Safety
Emergency procedure

2.9.3 Power failure / induced draught fan failure

2.9.4 Fire in the system

Operating Instructions SP Dual compact | B1500319_en
A power failure, among others, can be identified based on the following points:
▪ Display remains dark despite touching it
▪ LED status does not flash / light up
▪ No noise from the units (e.g. induced draught fan) can be heard
If the induced draught fan fails when there is power supply, the display shows the
error message "ID fan does not rotate, in spite of full
activation".
DANGER
In the event of a power failure or induced draught fan failure during heating mode:
The boiler is placed in an uncontrolled state. Life-threatening injury is possible
when opening the doors.
What to do in the event of a power failure / induced draught fan failure:
❒ Keep all the doors on the boiler closed
❒ Ventilate the room where the boiler is installed
❒ Close the fire door and doors to living areas
❒ Allow the fire to burn out completely and let the boiler cool
Recommendation: Equip the boiler with an uninterruptible power supply (USV,
photovoltaic system, etc.). This ensures correct combustion of the firewood and
prevents possible uncontrolled conditions (tarring of the heat exchanger, etc.).
Recommendation: Do not install smoke alarms and carbon monoxide detectors near
the system.
DANGER
In case of fire in the system:
Risk of death by fire and poisonous gases
Emergency procedure in case of fire:
❒ Leave the boiler room
❒ Close the doors
❒ Inform the fire department