4

4.2 Filling the pellet store

4.2.1 General advice for working in the store

26
CAUTION
Filling the store when the boiler is switched on
could result in damage and consequential injury!
When filling the fuel store:
❒ Switch off the boiler by tapping "Boiler OFF"
➥ The boiler follows the shutdown procedure and switches to "Off" status
❒ Allow the boiler to cool for at least half an hour
When the boiler has cooled down:
❒ Before filling check the store for fines and clean if necessary
➥ Observe the general advice for working in the store.
⇨ See "General advice for working in the store" [page 26]
❒ Close all openings to the store to seal out dust
❒ Fill the store with pellets
➥ Only use permitted pellets
⇨ See "Permitted fuels" [page 12]
Risk of injury due to moveable parts!
Shut off the feeder unit before entering the store!
When cleaning the store an increased amount of dust may be
generated. Wear a dust mask when working in the store.
Adequately ventilate the store before entering. Keep the door open
and always have a second person present. Observe the CO
concentration limit (< 30ppm).
Slick surfaces in the fuel store present a slipping hazard!
Unauthorised access prohibited! Keep children away!
Keep the fuel store locked and store the key in a safe place!
No fire, open flames or smoking in the store!
Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com
Operating the system
Filling the pellet store

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP Dual compact 15 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sp dual compact 20

Table of Contents