Troubleshooting
Extra cleaning of flue gas paths
Operating Instructions SP Dual compact | B1500319_en
❒ Open the front insulating door, fuel loading door and combustion chamber door
❒ Remove the front cover plate
❒ Remove the cover plate with servo-motor
➥ Note the servo-motor cable!
❒ Undo the four screws on the base plate as shown
❒ Fit the air volume throttle plate using the removed screws so that "SH W<15" can
be seen in the top part
❒ Fit the cover plate with servo-motor
6
77
Need help?
Do you have a question about the SP Dual compact 15 and is the answer not in the manual?