Intervals - Step 4/7

In this step, you can define the intervals for measurements and data transfers. The remaining
battery life is recalculated based on your entry.
Note
Calculated battery life
The calculated battery life is a statistical value. The actual remaining battery life may differ
depending on temperature influences or the connection quality of the Wi-Fi network.
Note
Effects that influence the battery life
Shorter intervals result in a shorter battery life.
The following intervals are preset in the factory:
• 5 minutes - interval for measuring temperature, vibrations, rotational frequency, operating
status
You can change these settings within a specified range.
• 10 minutes - interval to calculate speed, torque and energy consumption
This interval cannot be set, it is dependent on the selected measurement interval. The
calculation interval is three times as long, i.e. 3 minutes, for a
measurement interval of 1 minute. The calculation interval is twice as long for
measurement intervals 2 and 5 minutes. The calculation interval is the same length for all
other measurement intervals.
• 24 hours - interval for transmission of the stored data to "SIDRIVE IQ Fleet"
You can modify these settings within a preset range of 1 to 48 hours.
Note
To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes.
SIMOTICS CONNECT 400
Operating Instructions, 04/2023, A5E50161952B AL