Operation
7.2 Operation with iOS
Procedure
1. Open the "SIDRIVE IQ Config" application.
2. Select the required asset in the device overview.
3. Tap on the motor symbol
The connectivity module LED flashes.
7.2.3

Changing the measuring and send cycles

The following intervals are preset in the factory:
• 5 minutes - interval for measuring temperature, vibration, rotational frequency, operating
status
You can change these settings within a specified range.
• 10 minutes - interval to calculate speed, torque and energy consumption
This interval cannot be set, it is dependent on the selected measurement interval. The
calculation interval is three times as long, i.e. 3 minutes, for a measurement interval of 1
minute. The calculation interval is twice as long for measurement intervals 2 and 5 minutes.
The calculation interval is the same length for all other measurement intervals.
• 24 hours - interval for transmission of the stored data to SIDRIVE IQ Fleet
You can change these settings within a specified range of between 1 and 48 hours.
Note
Effects that influence the battery life
Shorter intervals result in a shorter battery life.
Note
To calculate the bearing status, the measuring cycle must be set to ≳ 5 minutes.