Siemens SIMOTICS CONNECT 400 Operating Instructions Manual page 138

Connectivity module
Hide thumbs Also See for SIMOTICS CONNECT 400:
Table of Contents

Advertisement

Maintenance
8.3 Basic functions (Android)
Function
Battery replacement
Restart
Reset to factory set‐
tings
Reset user credentials
136
Description
Sets the battery status display to 100% after battery replacement (Page 196).
The connectivity module restarts. The connection to the connectivity module is disconnected. Meas‐
urement data that have still not been transferred to SIDRIVE IQ Fleet are lost. To avoid this data loss,
run the "Send data to MindSphere" function before you restart the connectivity module.
Restores the factory settings of the connectivity module. The user credentials are reset to the factory
settings. All saved motor data and onboarding information are deleted.
Resets the user name and the connectivity module password to the factory settings.
Note:
This function requires additional entry of the Wi-Fi password. This ensures that only authorized
persons can reset the user login information. If the Wi-Fi has not yet been configured in SC400, the
"Wi-Fi password" field must remain empty.
SIMOTICS CONNECT 400
Operating Instructions, 04/2023, A5E50161952B AL

Advertisement

Table of Contents
loading

Table of Contents