Maintenance
8.6 Replacing a motor (Android)
Result
The following message is displayed after the motor has been successfully replaced.
After commissioning has been completed, you are automatically logged off from the device
and the Bluetooth connection is disconnected.
The connectivity module starts to record data and transfer data in the preselected intervals.
After the first measurements, a first connection is automatically established to SIDRIVE
IQ Fleet, which means that you can see the actual connection status shortly after
commissioning.
The connectivity module automatically starts the calibration procedure on the motor. It
requires 10 measuring cycles with the motor in the "ON" state and 10 measuring cycles with
the motor in the "OFF" state. Precise data is displayed in SIDRIVE IQ Fleet as an "operating
mode" signal only after the calibration process:
• Value "0": Motor off (OFF), sensor calibrated
• Value "1": Motor status not defined, sensor not calibrated
• Value "3": Motor on (ON), sensor calibrated
No additional measures are required to support calibration.