Configuring - First Steps; Configuring The Simolink Coupling Under Step 7 - Siemens SIMADYN D FM 458 User Manual

Application module
Table of Contents

Advertisement

4.4.4 Configuring - first steps

Using as an example a master-slave coupling, the necessary settings are
subsequently described which must be or should be observed when
configuring.
SIMATIC S7-400
FM
458
Slaves/transceiver
e.g. MASTERDRIVES MC or
automation system with ITSL / EXM 448-1
Fig. 4-10
Example for a master-slave coupling
Hardware
The SIMOLINK ring comprises the minimum of two and a maximum of
201 SLB modules, which are coupled to one another through fiber-optic
cables. There is only one SL master on a ring. All of the other nodes are
slaves.
An SLB module is a hardware component of an ITSL, an EXM 448-1
module or an option module SLB (SIMOLINK Board, Order No. 6SX7010-
0FJ00).
Additional information on these modules and their installation is
NOTE
provided in the User Manual D7-SYS "Hardware", or SIMOVERT
MASTERDRIVES Instruction Manual SLB SIMOLINK board.

4.4.4.1 Configuring the SIMOLINK coupling under STEP 7

For SIMATIC FM 458 with EXM 448-1, the basic clock cycle T0, possibly
the interrupt task Ix and the symbolic hardware assignment for the
SIMOLINK are set in the HW Config of STEP7 in the properties dialog
box.
The EXM 448-1 expansion module should be configured as EXM 448 in
NOTE
HWConfig.
Application Module FM 458 - User Manual
6DD1904-0AE0
Edition 12.2001
SL master
e.g. FM 458 with EXM 448-1
EXM
448-1
SLB-
Modul
SLB-
Mod-
ule
SIMOLINK ring
SLB-
SLB-
Mod-
Mod-
ule
ule
Configuring
SLB-
Mod-
ule
4-21

Advertisement

Table of Contents
loading

Table of Contents