R&S SpycerBox Cell Hardware Manual page 68

Table of Contents

Advertisement

Appendix

Troubleshooting
Error
An alarm is sounded.
The alarm cannot be
switched mute with
the mute button.
OR
At start-up the system
is not able to initialize
a disk set.
A-4
Cause
A hard disk or a hard
disk carrier got loose/
jammed (e.g. after
transport) or is not
mounted correctly.
A hard disk of the
hard disk tray is de-
fective.
A RAID controller is
defective.
SpycerBox Cell | Hardware Guide | Version 1.0
Solution
Shut down the system as described
in section "Shutting Down the Sys-
tem" on page 4-4. Then perform the
following: Pull all disk carriers partial-
ly out of the chassis and afterwards
install them again. See to it that they
are pulled out and reassembled cor-
rectly as described in section "Re-
placing a Hard Disk" on page 5-5.
After that start the system again.
Replace the defective disk as ex-
plained in section "Hard Disk Mainte-
nance" on page 5-2.
If you can rule out the above men-
tioned causes, a RAID controller may
be defective. Before attempting to
exchange a RAID controller (see sec-
tion "Controller Maintenance" on
page 5-13) contact the R&S DVS ser-
vice department.