The disk carrier of the replaced disk should be level with the others of
the array.
The respective LED on the hard disk will show you its state and therefore
a successful reassembling of the hard disk. You can configure SNMP or
use the SAN Remo configuration management software to check if re-
assembling the hard disk has been successfully completed as well. For
this, see the „SAN Remo Configuration Management" supplement.
4.
Cautiously push the disk tray back into the SpycerBox Cell.
Fasten the faceplate as described in section "Faceplate" on
5.
page 2-4.
Once the faceplate of the R&S DVS system is back in place, the replace-
ment of the hard disk is finished. After several minutes the replaced
hard disk will be automatically recognized by the system. Then the re-
build of the data will be initiated on its own. When the system has fin-
ished the rebuild, the R&S DVS system will be fully operational again.
Accessing the hard disk while rebuild takes place
Rebuild time depends on the load of the system. During a rebuild
the performance of the system will be affected and real-time pro-
cesses may not be possible.
It is recommended to avoid accesses or to at least to restrict
accesses to the disk array during this time, otherwise it may
take considerably longer.
SpycerBox Cell | Hardware Guide | Version 1.0
Rohde & Schwarz DVS GmbH
Maintenance

Hard Disk Maintenance
Figure 5-6: Moving up the lever
5-9