R&S SpycerBox Cell Hardware Manual page 55

Table of Contents

Advertisement

With the last step finished you have successfully replaced the defective
controller module. Now, you have to integrate the new controller mod-
ule in the existing configuration:
Switch the system on as described in section "Starting the Sys-
3.
tem" on page 4-2.
After the initial booting you will see an output that is similar to the fol-
lowing lines:
Following foreign Arrays are found:
<Array>
Press <Enter> to accept the current configuration
Press <Ctrl-A> to enter Adaptec RAID Configuration
Utility
Press <Ctrl-H> to Pause Configuration Messages
(Default i s not to accept if no valid key pressed in 30
seconds)
Press [Enter] on the keyboard to accept the configuration
4.
detected by the system.
Depending on the system you have purchased, you may see different
lines on the screen and you may have to press e.g. [F] on the
SpycerBox Cell to accept the configuration.
After this, the newly installed controller module automatically initiates
a verify of the connected hard disks which may take some time. When
finished, the system will continue its booting procedure until the oper-
SpycerBox Cell | Hardware Guide | Version 1.0
Rohde & Schwarz DVS GmbH
Maintenance

Controller Maintenance
Figure 5-11: Fixing the anchoring
5-17