Ethernet
Signal Interfaces
Digital Inputs
Nominal voltage
permanent voltage
Impulse voltage
Electric separation
Digital Outputs
Nominal voltage
Nomincal current per out-
Electric separation
Page 86 / 92
Norm
IEEE 802.3 (TCP/IP)
Connector
8-pole RJ45 socket
Bit rate
10 Mbits/s and 100 Mbits/s
IP address
parametrizable
Subnet
parametrizable
Function
Data output
Data protocol
RFC 854 (Telnet)
Number
3
Type
Current sinking / current sourcing (IEC type 1 current sinking); com-
mon reference potential
Type 24 V DC with 5 mA (R
Polarity
Plus or minus
Max. allowed
25.5 V DC
35 V DC for 0.5 s
Galvanic separation 250 V AC for 1 minute
Logic 1 (min.)
> 4.0 V DC
Logic 0 (max.)
< 2.5 V DC
Function
Individually selectable for each input via parametrization
Connector
Via a common 12-pole IO connector; spring force connection; nomi-
nal diameter 0.14 to 0.5 mm²; AWG 28 to 20; stripping length
8 mm; Connection according to norm EN-VDE; test points;
Connection of the common conductor via the current supply con-
nector.
Number
4
Type
MOSFET, electronic; current sinking / current sourcing (IEC type 1
current sinking); common reference potential
Type 24 V DC
Polarity
Plus or minus
Voltage range
5 to 30 V DC
Max. 450 mA
put
Galvanic separation 250 V AC for 1 minute
Logic 1 (min.)
23 V DC with maximum current
Logic 0 (max.)
0.1 V DC with 10 kΩ load
Function
Individually selectable via parametrization
Output shunt
Possible
Connector
Via common12-pole IO connector; spring force connection; Nominal
diameter 0.14 to 0.5 mm²; AWG 28 to 20; stripping length 8 mm;
Connection according to norm EN-VDE; test points;
Connection of the common conductor via the current supply con-
nector.
Gaussmeter IGM11 Operating Instructions
Chapter 12 Technical Data
typically 4.7 kΩ)
in