Installation

Driftwood Kit 1505DWKV2

Material required
• Black steel platform (supplied with appliance)
• Driftwood Kit containing:
• 6 logs
• 6 pebbles
• 1 bag of vermiculite
L18
L34
L35
Note:
Use of this log set may increase the possibility of
soot formation when air shutters are set to the
minimum setting. Although LT1 units are fitted
with a minimum air shutter stopper intended to
prevent sooting with most log sets, it is possible
some sooting may occur when using this log set
and the air shutter is set to minimum position.
Evaluate the flame picture carefully after the unit
has warmed up for fifteen minutes, and avoid
setting the air shutter to minimum when there
is limited rise in the venting system or the flame
appears overly luminous and lazy with smoke
trailing off the flame tips.
Refer to page 56 for the location and function of
the air shutter adjustment lever.
L33
L16
L36
Installation
1. Carefully unpack the kit, as the logs are fragile.
2. Install the steel platform around the burner as
indicated. The openings in the platform should be
underneath.
Installed platform
3. Carefully spread some of the vermiculite on the
surface of burner patting it gently with your hand to
form a single layer to the approximate level of the
top of the fl ange at the edge of the burner. Do not
pour too much to avoid blocking the burner ports.
NOTE: Ensure the area within the pilot shield is clear
of vermiculite.
Fuel Beds
Pilot shield