Installation
Refi t and Check Window
1. Place the window on its bottom supports (one at
each end) and center the window. Ensure the window
fl ange is at the bottom.
Bottom of
window fl ange
Bottom support
2. While holding the top of the window frame against
the fi rebox, pull and hook the top side levers to their
corresponding tabs on the window frame.
3. Hook the bottom side levers to their corresponding
tabs on the window frame. All four levers should
now be connected. Replace the tool under the fi re-
box.
4. Pull out top of window to test and ensure spring
loaded levers work properly, and repeat at the bot-
tom of the window.
5. Apply fi rm hand pressure around the window frame
to ensure the window is sealed tight against the
fi rebox.
6. If the Hot Glass Warning plate has been removed
from the front lower corner of the window, re-
install it by sliding it between the glass and the
frame as indicated.
Window Reinstallation & Check
WARNING
The window unit must be correctly
installed, fastened and sealed after
servicing or serious bodily injury and/or
damage to the appliance may result.
To ensure a safe operation:
• Double-check that the bottom of the
Window
frame
window frame is correctly installed on the
bottom supports;
• Verify that all 4 levers are hooked
properly to the window tabs then;
• Pull out the top of the window and
release it to ensure the springs return it,
and repeat at the bottom of the window;
• Ensure the window is sealed before
operation.
WARNING
Failure to install the window correctly can:
• Leak carbon monoxide.
• Affect the performance of the fireplace.
• Damage components.
• Cause overheating resulting in dangerous
conditions.
Damage caused by incorrect window
installation is not covered by the Valor
Warranty.
Hot Glass Warning Plate