Specifications - Valor LT1 2500KN Installation Manual

Direct vent zero clearance gas fireplace
Table of Contents

Advertisement

Specifications

Approval & Codes
This appliance is certifi ed to ANSI Z21.88/CSA 2.33
American National Standard / CSA Standard for Vented
Gas Fireplace Heaters for use in Canada and USA, and
to CGA 2.17-91 High Altitude Standard in Canada. This
appliance is for direct vent installations.
This appliance complies with CSA P.4.1-15 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or the Natural Gas
and Propane Installation Code CAN/CGA-B149.1. Only
qualifi ed licensed or trained personnel should install
this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70
or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in
w.c.)
Maximum Supply Pressure (in
w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
Input ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial and/or
local authorities having jurisdiction.
6
2500KN
2500KP
Natural
Propane
0-4,500 feet*
34,000
34,000
20,000
22,000
3.2"
9.0"
5"
11"
10"
14"
DMS#32
DMS#50
BL22N
BL14LP
220
160
Supply Gas
Heater engine 2500KN uses natural gas.
Heater engine 2500KP uses propane gas.
The supply pressure must be
between the limits shown in
the Ratings section.
The supply connection is 3/8"
NPT male and located on the
left hand side of the fi rebox.
A shut-off valve (not supplied)
is required on the supply
line to isolate the unit during service. See Gas Supply
Installation section for details.
Conversion Kits
The 2500K are supplied as natural gas or propane
gas and are fi eld convertible between fuels. See
instructions packaged with the conversion kits for
further information.
Electrical
The 2500K are designed to run on battery power and
do not require an electrical power source to operate
as a heater. However, they require electrical power to
operate the lights and optional GV60WIFI WiFi Kit.
WARNING
Electrical connection IS NOT ALLOWED
when adapting appliance for outdoor use.
HeatShift™System (Required)
The 2500K requires the installation of the HeatShift
System, a convection system that redistributes the
warm air fl ow away from the fi replace opening to a
more desirable location using natural convection,
without use of a fan.
The warm air fl ow may be relocated to a position higher
up the wall, out the sidewalls, or even to another room.
The result is much cooler wall temperatures above the
fi replace opening for locating televisions, artwork, etc.
Refer to "Appendix D—HeatShift™System™" on page
72 for more information.
Outdoor Conversion Kit
The 2500K models are supplied standard for indoor
applications and may be adapted for installation in
specifi c "outdoor" applications protected from weather
as defi ned in the GV60CKO outdoor conversion kit
manual.
X

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lt1 2500kp

Table of Contents