5.
After at least 30 seconds, go to the Hardware > Maintenance screen, and click
the right-arrow icon on the system controller to verify that the software has
detected that the drive is not present.
6.
On the replacement drive, open the release lever and slide the drive into the
same slot (1) until it is fully seated. Close the latch (2) to lock the drive in place.
Oracle ZFS Storage Appliance software automatically detects and configures the new drive.
7.
Go to the Maintenance > Hardware screen of the BUI, click the right-arrow
icon for the controller, and verify that the status icon
installed drive. To view details about the new drive, click its information icon.
8.
If a fault does not self-clear, see
Replacing a ZS4-4 Power Supply
Storage controllers are equipped with redundant, hot-swappable power supplies. If a power
supply fails and you do not have a replacement available, leave the failed power supply
installed to ensure proper air flow. A faulted power supply is indicated by an amber-colored
status LED. Use the following procedure to replace a ZS4-4 power supply.
Gain access to the rear of the storage controller where the power supplies are
1.
located.
2.
Disconnect the power cord from the faulted power supply.
"Repairing Active Problems" on page
Replacing a ZS4-4 Power Supply
is green for the newly
39.
Servicing the ZS4-4 Controller