Op. 55 000

BACK-UP ALARM

The back-up alarm serves as an audible warning de-
vice to alert bystanders and other machine operators
of machine movements. The alarm will only sound
when both hydrostatic control levers are stroked into
reverse. Refer to local codes for requirements.
IMPORTANT: Before servicing any switches or
alarm, disconnect the negative (–) battery ground
cable to avoid accidental shorts in the wiring system
when removing or installing components.
Alarm Location
The back-up alarm sound device should be located
to the inside and in the upper right rear corner of the
engine rear door at 1.
Adjustment
With the battery connected, and both hydrostatic
control levers in the neutral position, loosen and slide
both strikers, 1, rearward until the alarm sounds.
Move the strikers forward until the alarm stops
(approximately 1.5 mm [1/16"]) and tighten the hard-
ware.
Back-up Alarm Wiring
The alarm is a negative (–) ground system.
SECTION 88 - ACCESSORIES
19984978
88-10