FUEL LEVEL

Fuel level is shown to the operator by the fuel gauge
bar lights located in the center of the EIC display at
1. The operator will be signaled when the level is at
three bars and again at two bars. The bar lights, 2, will
flash continuously accompanied by an audible alarm
for about five seconds at each signal level.

EIC INTERLOCKS

EIC controls the fuel solenoid circuit. The operator
must be in the seat, with the seat belt fastened before
the engine will start and continue to run.
The EIC will lock the boom and bucket control valve
spools in neutral if the operator unfastens the seat
belt, leaves the seat, or turns the ignition key off. If the
operator is out of the seat for more than two seconds,
the seat belt must be unfastened and refastened to
enable the boom and bucket hydraulic systems to
function.
The unit is equipped with a "SERVICE/RUN" switch
for use during servicing and troubleshooting of the
skid steer. To access the Service/Run switch located
under the cab fuse panel cover, 1, loosen the two
thumbscrews, 2, and rotate cover, 1, to the side.
When the "SERVICE/RUN" switch, 3, is in the
"SERVICE" position, the engine will start but the
boom and bucket hydraulic system will be
inoperative.