bora Professional 3.0 Installation Instructions Manual page 41

Hide thumbs Also See for Professional 3.0:
Table of Contents

Advertisement

1
1
1
1
1
3
Fig. 4.83 PKAS3 connection diagram
[1]
Interface/control knob cable
[2]
Cooktop communication cable
[3]
Cooktop power supply cable
[4]
Power supply for each cooktop
[5]
PKAS3/PKAS3AB power supply cable (country-specific)
PKAS3/PKAS3AB power supply
[6]
[7]
Fan 2 power supply cable
[8]
Fan 2 control line
[9]
Home In connection cable
[10] Power supply for external device
[11] External device
[12] Home In port
[13] Home Out port
[M]
Fan 2
[S1] External switch contact
Special information for the Tepan stainless steel grill
The Tepan stainless steel grill is intended to be operated on a
supply network with a maximum impedance Zmax at the
transfer point (mains connection) of 0.0595 ohms . The user
is to ensure that the appliance is only operated on a mains
supply network which meets this requirement. If necessary,
ask the local energy supply company about the system
impedance.
Connecting the cooktop extractor to the power supply
u
Connect the extractor system (PKAS3) power supply cable and the
control unit (PKA3) power supply cable respectively to the power
supply.
u
Put the cooktop extractor into operation (see the operating
instructions).
u
Check that all the functions are working correctly.
Connecting the cooktop to the power supply
The power supply cable to be used (already pre-installed) must
comply with certain appliance-specific requirements.
www.bora.com
2
2
12 13
3
5
7
M
4
4
8
6
9
S1
11
10
A damaged power supply cable must be replaced by a
suitable power supply cable. This may only be done by an
authorised member of the After Sales Service team.
Power supply cable specifications and single-phase
connection diagram for PKFI3, PKI3, PKIW3, PKG3
Connection
Fuse protection Wire cross
1-phase
1 x 16 A
connection
Tab. 4.13 Fuse protection and minimum cross-section
Fig. 4.84 1-phase connection diagram
Power supply cable specifications and two-phase
connection diagram for PKC3, PKCB3, PKCH3, PKT3
Connection
Fuse protection Wire cross
1-phase
1 x 25 A
connection
2-phase
2 x 16 A
connection
Tab. 4.14 Fuse protection and minimum cross-section
Fig. 4.85 1-phase connection diagram
Fig. 4.86 2-phase connection diagram
Connecting the cooktop to the mains
u
Switch off the main switch/automatic circuit breaker before
connecting the cooktop.
u
Secure the main switch/automatic circuit breaker against being
switched back on without permission.
u
Make sure the power to the appliance is disconnected.
u
Only connect the cooktop using a permanent connection to a
power supply cable.
u
Check that installation has been carried out correctly.
Installation
Power supply
section
cable
1.5 mm²
Type H05VVH2-F
Power supply
section
cable
2.5 mm²
Type H05V2V2-F
2.5 mm²
Type H05V2V2-F
EN
41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pka3Pka3abPkfi3Pkiw3Pki3Pkcb3 ... Show all

Table of Contents