Installation
EN
Fig. 4.64 Connection diagram for the external switch contacts
u
Remove the snap-out element required for the cable feed from the
plastic housing of the control unit.
1
Fig. 4.65 Home Out contacts with strain relief
[1]
Strain relief clamp
Snap-out element for cable feed
[2]
u
Clamp the connection cable in the strain relief clamp provided in
accordance with the wire cross section or number of cables used.
u
Check the correct installation, as well as the firm positioning of the
connection cables.
u
Close and secure the control unit cover.
u
Screw down the lid with the screw provided (max. 2 Nm).
u
Make sure that the cable is not damaged or trapped.
u
If the Home-In interface is connected to PKAS3/PKAS3AB, the two
insulated wires of the connection cable must be joined together
with a cable tie.
36
2
Fig. 4.66 PKAS3 Home-In interface cable tie
[1]
Cable tie
[2]
Home-In interface PKAS3/PKAS3AB
Insulated wire
[3]
1
Fig. 4.67 Home Out contacts with strain relief
Strain relief clamp
[1]
[2]
Snap-out element for cable feed
1
1
Fig. 4.68 Fitting the strain relief clamp
[1]
Strain relief clamp
1
2
3
2
1