[1]
Cooktop
Rear cooking zone (zone 1)
[2]
[3]
Front cooking zone (zone 2)
[4]
Rear cooking zone control knob (zone 1)
[5]
Front cooking zone control knob (zone 2)
Special instructions for the wok cooktop PKIW3
As the wok cooktop PKIW3 only has one cooking zone, in the case of
a connection with 2 control knobs it does not matter how the
connections are arranged (see the operating instructions).
If the wok cooktop PKIW3 is installed with 2 control knobs, it can be
operated with either the left or the right control knob.
Connecting the cooking zone in the case of 1 control knob
Solely connect the port on the back of the control knob to the
u
zone 1 port on the cooktop.
Connecting the cooking zone in the case of 2 control knobs
u
Connect the ports on the back of the control knob to the ports on
the cooktop (zone 1 or zone 2).
4.13.2 Ports on cooktop extractor system
PKAS3
1
5
4
3
2
Fig. 4.77 Rear ports on PKAS3
Home In
[1]
[2]
Home In
[3]
Additional fan control line
[4]
Additional fan power supply cable
[5]
Power supply cable with microfuse
Connecting an additional fan
u
Connect the additional fan control line to the port provided on the
back of the appliance.
Connect the additional fan power supply cable to the port provided
u
on the back of the appliance.
u
Check all the plug connections to ensure that they are secure.
4.13.3 Connecting cooktop extractor
PKA3
Connecting the control unit and fan to the cooktop
extractor
u
Using the CAT 5e communication cable (included in the scope of
delivery) connect the port on the side of the cooktop extractor to
the port on the control unit.
Connect the plinth fan control line to the control unit.
u
www.bora.com
Connect the plinth fan power supply cable to the control unit.
u
1
Fig. 4.78 Side port for the control unit on cooktop extractor PKA3
[1]
Control unit port
1
2
Fig. 4.79 Control unit ports
CAT 5e communication cable socket
[1]
Control unit socket for fan 2
[2]
[3]
Control unit socket for fan 1
[4]
Mains cable socket for fan 2
[5]
Mains cable socket for fan 1
[6]
Mains cable socket with micro fuse
2
Fig. 4.80 Plinth fan connection plugs
[1]
Fan mains cable connection plug
[2]
Fan control cable connection plug
Removing the power supply cable
To remove the power supply cable from the control unit you need a
small slotted screwdriver.
Disconnect the control unit power supply cable from the power
u
supply.
u
Make sure that there is no power to the appliance.
u
Use the slotted screwdriver to undo the lock on the fan power
supply cable plug.
To do this, insert the slotted screwdriver into the gap in the socket.
u
u
Press the lock down gently.
u
Use the slotted screwdriver to gently lever the power supply cable
plug out of the control unit socket.
Installation
3
4
5
6
1
EN