Fig. 4.60 Stripping lengths and installation position of the PKA3/
PKA3AB connection cable
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
[4]
Strain relief clamp
Cable feed snap-out element
[5]
PKAS3/PKAS3AB
Please adhere to the maximum stripping length of the individual
u
wires of 9 mm on the stripped wire end.
u
Please adhere to the maximum stripping length of the outer sheath
of 21 mm (Home In) and 16.5 mm (Home Out) on the insulated
wire.
1
2
Fig. 4.61 Stripping lengths and installation position of the PKAS3/
PKAS3AB connection cable – Home In
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
Strain relief clamp
[4]
Cable feed snap-out element
[5]
www.bora.com
3
4
5
3
4
5
1
Fig. 4.62 Stripping lengths and installation position of the PKAS3/
PKAS3AB connection cable – Home Out
[1]
Stripped wire end
[2]
Insulated wire
[3]
Jacketed cable
[4]
Strain relief clamp
Cable feed snap-out element
[5]
4.12.4 Installing the external switch
device
Depending on the type of switch device, connect the connection
cables to either the Home In or the Home Out connection clamp.
u
Adhere to the connection diagram when connecting Home In and
Home Out.
u
Connect the cable for the relevant contact to the switch contact
clamp in accordance with the connection diagram.
T
In order to connect the Home-In interface, the installed bridge
must be removed.
T
The Home In contact must be bridged if this is not used (bridged
on delivery).
T
For connections to the Home In connection clamp, no ferrules may
be used.
Fig. 4.63 Connection diagram for the external switch contacts PKA3
Installation
2
3
4
5
EN
35