5.04

Fault Indicator

At initial power up, two lights will temporarily illuminate for 2-3 seconds to show the version of software used.
To determine the first digit, count the function indicators left to right, 1 through 5. To determine the second
digit count the pressure indicators, reading from bottom to top, 0 through 7. In the example below the Temp
indicator and 75 psi indicators are ON indicating the version would be 2.3.
!
When the
"Fault" indicator is ON or blinking it will be accompanied by one of the pressure indicator
lights depending on what the fault is. The following table explains each of those Faults.
NOTE!
Fault explanations are covered in the following tables.
Manual 0-5404
7
6
5
A
MAX
MIN
PSI
BAR
MAX
MAX
4
3
2
1
MIN
MIN
0
!
1 2 3 4
5
Pressure
Fault
Indicator
Max
Over Pressure
90
Internal Error
85
Shorted Torch
80
Consumables Missing
75
Start Error
70
Parts in Place
65
Input Power
Min
Under Pressure
SERVICE