4.
Crimp the RJ-45 connector with the crimping pliers until you hear a click.
5.
Repeat steps 2 to 5 to attach a connector to the other end of the cable.
Verifying the cable
Examine the assembled twisted pair connectors. If the cable cannot meet the following requirements,
reassemble the cable:
The connector surface must not contain obvious foreign objects, dirt or rust.
The wires must be extended to the front of the RJ-45 end as close as possible.
The end and front faces of the metal plating and the plastic spacer are not skewed or defective.
The wires are arranged in the correct sequence.
Use a cable tester to verify the connectivity of the cable:
1.
Insert the cable connectors into the RJ-45 female ports on the tester in turn.
2.
Gently shake the connectors of the twisted pair cable to confirm that the connectors are in
reliable contact with the RJ-45 female ports.
3.
Switch on the tester, and view the LEDs on the master and remote terminals.
For a straight-through cable, when master LEDs 1 through 8 and G are lighted in sequence,
the same-numbered LEDs on the remote terminal should be lighted.
For a crossover cable, when master LEDs 1 through 8 and G are lighted in sequence, the
LED lighting sequence on the remote terminal should be 3-6-1-4-5-2-7-8-G.
FigureB-11 Cable tester (straight-through network cable)
(1) Master terminal
1
2
(2) Remote terminal
6

Advertisement