Engineering Labels For Optical Fibers - H3C CR16000-M Installation Manual

Hide thumbs Also See for CR16000-M:
Table of Contents

Advertisement

Content
MN-Z
The information provided on the following labels is different, subject to different devices that the
Ethernet cables are connecting. For example:
On a label for the Ethernet cable that connects a router and a server:
For the router end—Rack number, chassis number, and Ethernet port number on the
router.
For the server end—Rack number and chassis number, or the specific location of the
server if the server is laid separately.
On a label for the Ethernet cable that connects the router and a terminal:
For the router end—Rack number, chassis number, and Ethernet port number, or the
specific location of the router if the router is laid separately. The definitions of the rack
number and chassis number are the same as those described in TableA-1.
For the terminal end—Ethernet port number of the terminal.
FigureA-9 Example of a label on an Ethernet cable
A01
01
A01-01-05-05-R—The local end of the Ethernet cable is connected to Ethernet Port 05, Slot 05,
Chassis 01 of the rack on Row A, Column 01 in the equipment room.
G02-01-01-01-T—The peer end of the Ethernet cable is connected to Ethernet Port 01, Slot 01,
Chassis 01 of the rack on Row G, Column 02 in the equipment room.

Engineering labels for optical fibers

These labels are affixed to optical fibers that connect the fiber ports on the cards in a chassis, or
connect fiber ports on box-type devices. There are two types of labels for optical fibers: labels for a
fiber that connects the fiber ports on two devices, labels for a fiber that connects the device and the
optical distribution frame (ODF).
Meaning
C—Slot number
D—Ethernet port number
MN—Rack number
Z—Location number
05
05
R
Example
example, 01.
Numbered in top-down and left-right order with two
digits, for example, 01.
Numbered in top-down and left-right order with two
digits, for example, 01.
M—Row number of the rack in the equipment
room, in the range of A to Z.
N—Column number of the rack in the equipment
room, in the range of 01 to 99.
For example, B02.
Location number of the terminal or device onsite.
If you connect the cable to a router in a rack, specify
the rack number, chassis number, and Ethernet port
number, for example, B02-03-12. If you connect the
cable to a terminal or an NMS, specify the location
number of the terminal or the NMS.