Page 1
H3C CR16000-F Routers Hardware Information and Specifications New H3C Technologies Co., Ltd. http://www.h3c.com Document version: 5W100-20231023...
Page 2
The information in this document is subject to change without notice. All contents in this document, including statements, information, and recommendations, are believed to be accurate, but they are presented without warranty of any kind, express or implied. H3C shall not be liable for technical or editorial errors or omissions contained herein.
Page 3
Preface This document describes the hardware information and specifications for the H3C CR16000-F routers, including router overview, removable module compatibility and specifications, and cables. This preface includes the following topics about the documentation: • Audience. • Conventions. • Documentation feedback.
Page 4
Symbols Convention Description An alert that calls attention to important information that if not understood or followed WARNING! can result in personal injury. An alert that calls attention to important information that if not understood or followed CAUTION: can result in data loss, data corruption, or damage to hardware or software. An alert that calls attention to essential information.
Page 5
Documentation feedback You can e-mail your comments about product documentation to info@h3c.com. We appreciate your comments.
• The available chassis models and accessories vary by country and region. This document describes only the preceding models. For the chassis models and accessories available in your country or region, contact the local H3C marketing personnel. Figure 1 CR16006-F front and rear views...
Page 8
Figure 2 CR16010-F (one fan tray) front and rear views (1) Service modules (slots 0 to 3 and slots 6 to 9) (2) MPUs (slots 4 and 5) (3) Power supplies (4) Fan tray (5) Switching fabric modules (slots 10 to 13)
Page 9
Figure 3 CR16010-F (two fan trays) front and rear views (1) Service modules (slots 0 to 3 and slots 6 to 9) (2) MPUs (slots 4 and 5) (3) Power supplies (4) Fan trays (5) Switching fabric modules (slots 10 to 13)
Page 10
Figure 4 CR16010H-F (five switching fabric modules)/CR16010H-FA front and rear views (1) MPUs (slots 0 and 1) (2) Service modules (slots 2 to 9) (3) Power supplies (4) Power switches (5) Air duct (6) Fan trays (7) Switching fabric modules (slots 10 to 14) (slot 11 can be used only when five switching fabric modules are required)
Page 11
Figure 5 CR16010H-F (four switching fabric modules) front and rear views (1) MPUs (slots 0 and 1) (2) Service modules (slots 2 to 9) (3) Power supplies (4) Power switches (5) Fan trays (6) Switching fabric modules (slots 10 to 13)
Page 12
Figure 6 CR16014-F front and rear views (1) Service modules (slots 0 to 5 and slots 8 to 13) (2) MPUs (slots 6 and 7) (3) Power supplies (4) Fan trays (5) Switching fabric modules (slots 14 to 17)
Page 13
Figure 7 CR16018-F (five switching fabric modules)/CR16018-FA front and rear views (1) Service modules (slots 0 to 15) (2) MPUs (slots 16 and 17) (3) Power supplies (4) Power switches (5) Air duct (6) Fan trays (7) Switching fabric modules (slots 18 to 22) (slot 19 can be used only when five switching fabric modules are required)
Page 14
Figure 8 CR16018-F (four switching fabric modules) front and rear views (1) Service modules (slots 0 to 15) (2) MPUs (slots 16 and 17) (3) Power supplies (4) Power switches (5) Fan trays (6) Switching fabric modules (slots 18 to 21)
(4) MPUs (slots 8 and 9) (5) Power supplies (6) Power switch (7) Fan trays Device slots and slot numbering Module slot numbering The slot numbering sequence for all models of CR16000-F follows the principle of front-to-back, top-to-bottom, and left-to-right.
Page 16
Table 1 Module slot numbering MPU location Model Numbering CR16006-F, CR16010H-F, Figure 11 (CR16006-F is used as an Upper front and CR16010H-FA example) CR16010-F, CR16014-F, Figure 12 (CR16014-F is used as an Middle upper CR16005E-F, CR16010E-F example) CR16018-F (four switching fabric modules), CR16018-F Figure 13 (CR16018-F with five switching...
Figure 14 Slot numbering on the CR16005E-F Figure 15 Slot numbering on the CR16010E-F Interface module slot numbering and interface numbering The slot numbering sequence for all interface modules follows the principle of top-to-bottom and left-to-right. For example, as shown in Figure 16, if you install MIC-GP4L interface modules on the CSPEX-1504X, white-background numbers represent interface numbers, and green-background...
Figure 16 Subslot numbering and interface numbering Power supply slot numbering The slot numbering sequence for all models of CR16000-F follows the principle of left-to-right and top-to-bottom. • For example, on the CR16006-F, the power supply slots are number 0 through 3 from the left to...
CR16010E-F: Slot 10 and Slot11 Interface numbering Interface numbering The CR16000-F supports varies types of interfaces, including console ports, USB console ports, GE ports, XGE ports, network management ports, and POS interfaces. The interfaces are numbered according to the following rules: The number of an interface is in the interface-type slot/subslot/num format, where: •...
If an MIC-GP4L interface submodule is installed in slot 1 on the CSPEX-1504X, GigabitEthernet interfaces on the submodule are numbered as follows: − GigabitEthernet 3/1/1 − GigabitEthernet 3/1/2 − GigabitEthernet 3/1/3 − GigabitEthernet 3/1/4 If an MIC-GP4L interface submodule is installed in slot 2 on the CSPEX-1504X, ...
Page 22
CR16010-F (single CR16010-F (dual fan Item CR16006-F fan tray) trays) Number of MPU slots Number of service modules Number of switching fabric modules Number of power supply slots Number of fan tray slots • • • Fan noise (room Fan noise (room Fan noise (room temperature): 62.3 temperature): 61.6...
Page 25
Item CR16005E-F CR16010E-F • Operating: 10% RH to 95% RH (noncondensing) Relative humidity • Storage: 5% RH to 95% RH (noncondensing) ≤ 5000 m (16404.20 ft) Altitude NOTE: • Rack Unit (RU) is a measurement unit used to indicate the height of a rack. 1 RU is equal to 44.45 mm (1.75 in).
FRUs and compatibility matrixes For compatibility between the cards and the software release, see the release notes. For compatibility between the cards and transceiver modules, see the cards and transceiver modules compatibility matrixes for the device. NOTE: • This document uses the identifier printed on a card or subcard as its model name. •...
Page 31
LED mark Status Description The following are the possible causes: • The MPU is in standby state. • The MPU has failed. To identify the failure, see the card status LED description. Table2-2 Card status LED description Status Description RUN (Green) ALM (Red) Flashing green (once every 2...
Page 32
Table2-5 CF card LED description Status Description Steady green The CF card is present and idle. Do not hot swap it. The CF card is present and the system is reading/writing the card. Do Flashing green CF card not hot swap it. The CF card is not in position, or the CF card is in offline state.
Page 33
Table2-8 Management Ethernet port specifications Item Description Connector type RJ-45 Port quantity Transmission baud rate 10/100/1000 Mbps Transmission medium and max Category-5 or above twisted pair cable, with a transmission distance of transmission distance 100 m (328.08 ft) Services For router software upgrade and network management USB port USB ports can connect multiple types of devices and provide a higher data transfer rate than common parallel interfaces and serial interfaces.
Item Description Maximum power 53 W consumption Power consumption (with typical 47 W configuration) Minimum power 46 W consumption Operating temperature 0°C to 45°C (32°F to 113°F) SDRAM 8 GB or 16 GB (subject to the card specifications) CSR05SRP1L3 View Figure2-2 CSR05SRP1L3 view (1) High-precision time synchronization ports (Both are input ports by default.
Page 35
LED mark Status Description The following are the possible causes: • The MPU is in standby state. • The MPU has failed. To identify the failure, see the card status LED description. Table2-13 Card status LED description Status Description RUN (Green) ALM (Red) Flashing green (once every 2...
Page 36
Table2-16 CF card LED description Status Description Steady green The CF card is present and idle. Do not hot swap it. The CF card is present and the system is reading/writing the card. Do Flashing green CF card not hot swap it. The CF card is not in position, or the CF card is in offline state.
Page 37
Table2-19 Management Ethernet port specifications Item Description Connector type RJ-45 Port quantity Transmission baud rate 10/100/1000 Mbps Transmission medium and max Category-5 or above twisted pair cable, with a transmission distance of transmission distance 100 m (328.08 ft) Services For router software upgrade and network management USB port USB ports can connect multiple types of devices and provide a higher data transfer rate than common parallel interfaces and serial interfaces.
Page 38
Item Description Compliant standard GJB681 Transmission baud 2.048 Mbps rate Transmission 75-ohm coaxial cable medium Sends and receives 2.048 MHz clocks and 2.048 Mbps signals to synchronize the Services clocks of the router and other devices, such as routers and the terminals. High-precision time synchronization port Table2-23 High-precision time synchronization port specifications Item...
CSR05SRP1P1 View Figure2-3 CSR05SRP1P1 view (1) USB console port (2) USB 2.0 port (3) Management Ethernet ports (10/100/1000Base-T) (port 1 reserved for future (4) Console port use) (6) MPU active/standby LED. For the LED (5) System reset button description, see Table2-25. (7) Card status LEDs.
Page 40
Status Description RUN (Green) ALM (Red) Steady on Steady on The card in the corresponding slot is starting or faulty. No card is available in the corresponding slot. NOTE: At the system startup, the ALM LED being on for a while does not mean that the card is faulty. Table2-27 Power supply status LED description Status Description...
Page 41
Table2-30 Console port specifications Item Description Connector type RJ-45 Compliant standard Asynchronous EIA/TIA-232 ≤ 115200 bps. The default value is 9600 bps. Transmission baud rate Transmission medium and max Common asynchronous serial interface cable, with a maximum transmission distance transmission distance of 15 m (49.21 ft) Connects to the serial port on a local PC running a terminal Services emulation program.
Table2-33 USB port specifications Item Description Connector type USB A Compliant standard USB 2.0 Services External storage media NOTE: Extension cables are not supported. Technical specifications Table2-34 Technical specifications Item Description Dimensions (H × W × 52.2 × 399 × 352 mm (2.06 × 15.71 × 13.86 in) Weight 4.30 kg (9.48 lb) Maximum power...
Page 43
(7) Console port (8) System reset button (9) MPU active/standby LED. For the LED (10) Card status LEDs. For the LED description, see description, see Table2-35. Table2-36. (11) Power supply status LED. For the LED (12) Fan tray status LED. For the LED description, description, see Table2-37.
Page 44
Status Description OK (Green) FAIL (Red) the power supply is faulty, the power supply is not powered on, the power cable is faulty, or the external power supply system has a power outage. The following are the possible causes: No power supplies exist in the chassis. No power supply in the chassis has power output, because the power supplies are faulty, the power supplies are not powered on, the power cables are faulty, or the external power supply system has a power...
Page 45
Item Description Compliant standard Asynchronous EIA/TIA-232 ≤ 115200 bps. The default value is 9600 bps. Transmission baud rate Transmission medium and max Common asynchronous serial interface cable, with a maximum transmission distance transmission distance of 15 m (49.21 ft) Connects to the serial port on a local PC running a terminal Services emulation program.
Page 46
Item Description Services External storage media NOTE: Extension cables are not supported. CF card slot A CF card is a mobile storage device that features fast speed, large capacity, small size, light weight, and low power consumption. Table2-45 External CF card specifications Item Description CF card slots...
Item Description Synchronizes the clocks of the router and other devices, such as GPS receivers and terminals. Technical specifications Table2-48 CSR05SRP1P3/CSR05SRP1P3A MPU Item Description Dimensions (H × W × D) 52.2 × 399 × 352 mm (2.06 × 15.71 × 13.86 in) CSR05SRP1P3: 4.80 kg (10.58 lb) Weight CSR05SRP1P3A: 4.40kg (9.70 lb)
Page 48
LEDs Table2-49 MPU active/standby LED description LED mark Status Description Steady green The MPU is in active state. The following are the possible causes: • The MPU is in standby state. ACTIVE • The MPU has failed. To identify the failure, see the card status LED description.
Page 49
Fan tray status Status Description The router is not powered on. Table2-53 Management Ethernet port LED description LED mark Status Description Flashing green The port is in sending or receiving data. LINK/ACT Steady green A link is present on the port. No link is present on the port.
Page 50
Table2-56 Management Ethernet port specifications Item Description Connector type RJ-45 Port quantity Transmission baud rate 1000 Mbps, full duplex Transmission medium and max Category-5 or above twisted pair cable, with a transmission distance of transmission distance 100 m (328.08 ft) Services For router software upgrade and network management USB port...
Item Description Transmission medium Category-5 or above twisted pair cable You can configure the port as an input port or output port at the CLI. Services Synchronizes the clocks of the router and other devices, such as GPS receivers and terminals. Technical specifications Table2-60 Technical specifications Item...
Page 52
The views of the CSR05SRP1R3 and CSR05SRP1R3A are similar. This figure uses the CSR05SRP1R3 as an example. LEDs Table2-61 MPU active/standby LED description LED mark Status Description Steady green The MPU is in active state. The following are the possible causes: •...
Page 53
Table2-64 Fan tray status LED description Status Description OK (Green) FAIL (Red) Steady on The fan tray is operating correctly. One or more fans in the fan tray have failed or the fan tray is not in Steady on position. The router is not powered on.
Page 54
Item Description Connects routers to PCs or similar terminals that do not have a serial port. Management Ethernet port Connects to a computer for router program loading and router debugging, or connects to a remote NMS for remote management. Table2-68 Management Ethernet port specifications Item Description Connector type...
High-precision time synchronization port Table2-71 High-precision time synchronization port specifications Item Description Connector type RJ-45 Compliant standard QB-B-016-2010 Transmission baud rate 9600 bps Transmission medium Category-5 or above twisted pair cable You can configure the port as an input port or output port at the CLI. Services Synchronizes the clocks of the router and other devices, such as GPS receivers and terminals.
Page 56
(10/100/1000Base-T) (3) System reset button (4) USB 2.0 port (5) High-precision time synchronization ports (Both are input ports by default. When both ports are input (6) SMB coaxial clock output ports (2 in total) ports, only port 1 takes effect.) (8) MPU active/standby LED.
Page 57
Table2-76 Card status LED description LED mark Status Description Flashing green The card in the corresponding slot is operating correctly. The service module in the corresponding slot is loading Fast flashing green software. If the card keeps in this state, the current software (4 Hz) version of the device is not running the software version compatible with the card.
Page 58
Table2-79 Console port specifications Item Description Connector type RJ-45 Compliant standard Asynchronous EIA/TIA-232 ≤ 115200 bps. The default value is 9600 bps. Transmission baud rate Transmission medium and max Common asynchronous serial interface cable, with a maximum transmission distance transmission distance of 15 m (49.21 ft) Connects to the serial port on a local PC running a terminal Services emulation program.
Item Description Transmission baud rate 2.048 Mbps Transmission medium 75-ohm coaxial cable Sends and receives 2.048 MHz clocks and 2.048 Mbps signals to synchronize Services the clocks of the router and other devices, such as routers and the terminals. Technical specifications Table2-83 Technical specifications Item Description...
Page 60
LEDs Table2-84 MPU active/standby LED description LED mark Status Description Steady green The MPU is in active state. The following are the possible causes: • The MPU is in standby state. ACTIVE • The MPU has failed. To identify the failure, see the card status LED description.
Page 61
LED mark Status Description No card is available in the corresponding slot. NOTE: At the system startup, the ALM LED being on for a while does not mean that the card is faulty. Table2-88 Management Ethernet port LED description Status Description LINK (Green) ACT (yellow)
Page 62
USB ports can connect multiple types of devices and provide a higher data transfer rate than common parallel interfaces and serial interfaces. Table2-91 USB port specifications Item Description Connector type USB A Compliant standard USB 2.0 Services External storage media NOTE: Extension cables are not supported.
Item Description Maximum power 160 W consumption Power consumption (with 103 W typical configuration) Minimum power 95 W consumption Operating temperature 0°C to 45°C (32°F to 113°F) SDRAM 16 GB or 32 GB (subject to the card specifications) Compatibility information Table2-95 Compatibility matrix between MPUs and routers Card model Applicable router models...
CSPC-CP1LCX View Figure2-9 CSPC-CP1LCX view (2) CFP port LED. For the LED description, see (1) 100GBASE-R-CFP fiber port (1 in total) Table2-96. LEDs Table2-96 CFP port LED description Status Description The CFP port is sending or Flashing receiving data. A link is present on the CFP CFP port LED Steady on port.
Item Description Minimum power 115 W consumption Operating temperature 0°C to 45°C (32°F to 113°F) CSPC-CP2LB View Figure2-10 CSPC-CP2LB view (2) CFP port LED. For the LED description, see (1) 100GBASE-R-CFP fiber ports (2 in total) Table2-99. LEDs Table2-99 CFP port LED description Status Description Flashing...
Item Description Weight 4.06 kg (8.95 lb) Maximum power 197 W consumption Power consumption (with typical 178 W configuration) Minimum power 150 W consumption Operating temperature 0°C to 45°C (32°F to 113°F) CSPC-GE16XP4L-E View Figure2-11 CSPC-GE16XP4L-E view (1) 10GBASE-R-SFP+ fiber ports (4 in total) (10GE (2) Combo interfaces (16 in total) (10GE SFP+ SFP+ modules supported) modules supported in 1000BASE-X-SFP fiber ports)
Status Description Steady on A link is present on the port. No link is present on the port. Table2-104 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port.
Page 68
Figure2-12 CSPC-GE24L-E view (1) Combo interfaces (24 in total) (10GE SFP+ (2) SFP port LED. For the LED description, see modules supported in 1000BASE-X-SFP fiber ports) Table2-108. (3) RJ-45 Ethernet Interface LED. For the LED description, see Table2-107. LEDs Table2-107 RJ-45 Ethernet port LED description Status Description The port is sending or receiving...
Item Description Weight 4.45 kg (9.81 lb) Maximum power 114 W consumption Power consumption (with typical 110 W configuration) Minimum power 108 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature CSPC-GP24GE8XP2L-E View Figure2-13 CSPC-GP24GE8XP2L-E view (1) 10GBASE-R-SFP+ fiber ports (2 in total) (10GE (2) 1000BASE-X-SFP fiber ports (24 in total) (GE SFP+ modules supported) SFP modules supported)
Page 70
Status Description data. Steady on A link is present on the port. No link is present on the port. Table2-113 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port.
CSPC-GP24LA1 View Figure2-14 CSPC-GP24LA1 view (1) 1000BASE-X-SFP fiber ports (16 in total) (2) Combo interfaces (8 in total) (3) SFP port LED. For the LED description, see (4) RJ-45 Ethernet port LED. For the LED description, see Table2-117. Table2-116. NOTE: •...
Port Connector Port Card model Description transmission type quantity speed RJ45 10/100/1000 Mbps 16-port 1000BASE-X 155 Mbps Ethernet optical interface CSPC-GP24LA1 (SFP, LC) + 8-port combo 1000 Mbps interface module (A Type) 10/100/1000 Mbps Technical specifications Table2-119 Technical specifications Item Description Dimensions (H ×...
Page 73
LEDs Table2-120 RJ-45 Ethernet port LED description Status Description The port is sending or receiving Flashing data. RJ-45 Ethernet port LED Steady on A link is present on the port. No link is present on the port. Table2-121 SFP port LED description Status Description The port is sending or receiving...
Item Description Power consumption (with typical 90 W configuration) Minimum power 51 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature CSPC-GP44XP4LCX View Figure2-16 CSPC-GP44XP4LCX view (1) 1000BASE-X-SFP fiber ports (44 in total) (2) 10GBASE-R-SFP+ fiber ports (4 in total) (3) SFP port LED.
NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps. Ports Table2-127 Port specifications Port Connector Port Card model Description transmission type...
(2) SFP port LED. For the LED description, see (1) 1000BASE-X-SFP fiber ports (48 in total) Table2-129. LEDs Table2-129 SFP port LED description Status Description The port is sending or receiving Flashing data. SFP port LED Steady on A link is present on the port. No link is present on the port.
Page 77
Figure2-18 CSPC-GT48LA1 view (1) 10/100/1000BASE-T copper ports (48 in (2) RJ-45 Ethernet port LED. For the LED description, total) see Table2-132. LEDs Table2-132 RJ-45 Ethernet port LED description Status Description The port is sending or receiving Flashing data. RJ-45 Ethernet port LED Steady on A link is present on the port.
CSPC-XLP6LCX View Figure2-19 CSPC-XLP6LCX view (2) QSFP+ port LED. For the LED description, see (1) 40GBASE-R-QSFP+ fiber ports (6 in total) Table2-135. LEDs Table2-135 QSFP+ port LED description Status Description The QSFP+ port is sending or Flashing receiving data. A link is present on the QSFP+ QSFP+ port LED Steady on port.
Item Description Maximum power 290 W consumption Power consumption (with typical 261 W configuration) Minimum power 181 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature CSPC-XP12LAX/CSPC-XP12LCX View Figure2-20 CSPC-XP12LCX view (2) SFP+ port LED. For the LED description, see (1) 10GBASE-R-SFP+ fiber ports (12 in total) Table2-138.
Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port. NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps.
Page 82
Figure2-22 CSPC-XP2LA1 view (2) XFP port LED. For the LED description, see (1) 10GBASE-R-XFP fiber ports (2 in total) Table2-144. LEDs Table2-144 XFP port LED description XFP port LED status Description LINK Steady on Flashing green A link is present, and the XFP port is sending or receiving data. Steady on A link is present, but the XFP port is not sending or receiving data.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature CSPC-XP4LB View Figure2-23 CSPC-XP4LB view (2) XFP port LED. For the LED description, see (1) 10GBASE-R-XFP fiber ports (2 in total) Table2-147. LEDs Table2-147 XFP port LED description XFP port LED status Description LINK Steady on...
Item Description Weight 2.93 kg (6.46 lb) Maximum power 80 W consumption Power consumption (with typical 72 W configuration) Minimum power 53 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature CSPC-XP8LB View Figure2-24 CSPC-XP8LB view (2) SFP+ port LED. For the LED description, see (1) 10GBASE-R-SFP+ fiber ports (8 in total) Table2-150.
CR16010H-F CR16010H-F (with five fabric (with four fabric CR16006-F, modules), modules), CR16005E-F, Card model CR16010-F, CR16018-F (with CR16018-F (with CR16010E-F CR16014-F five fabric four fabric modules), modules) CR16018-FA CSPC-XP4LB Supported Not supported Not supported Not supported CSPC-XP8LB Supported Not supported Not supported Not supported CSPC-GP48L...
The views of CEPC-CP4RX and CEPC-CP4RXA are similar. This figure uses the CEPC-CP4RX as an example. LEDs Table2-154 CFP2 port LED description Status Description The CFP2 port is sending or receiving Flashing data at 100 Gbps. CFP2 port LED A 100 Gbps link is present on the CFP2 Steady on port.
Page 88
Figure2-26 CEPC-CP4RX-L view (1) 100GBASE-QSFP28 fiber ports (4 in total) (100G QSFP (2) QSFP 28 port LED. For the LED 28 modules supported) description, see Table2-157. LEDs Table2-157 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving Flashing data at 100 Gbps.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature CEPC-CQ16L1 View Figure2-27 CEPC-CQ16L1 view (1) 100GBASE-QSFP28 fiber ports (8 in total) (100G QSFP (2) QSFP 28 port LED. For the LED 28 modules supported) description, see Table2-160. LEDs Table2-160 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving...
Item Description Dimensions (H × W × 52.5 × 399 × 370 mm (2.07 × 15.71 × 14.57 in) Weight 8.25 kg (18.19 lb) Maximum power 1240 W consumption Power consumption (with typical 970 W configuration) Minimum power 760 W consumption Operating 0°C to 45°C (32°F to 113°F)
Table2-164 Port specifications Port Connector Port Card model Description transmission type quantity speed 8-port 100G Ethernet optical CEPC-CQ8L interface line processing unit 100 Gbps (QSFP28, LC) 8-port 100G Ethernet optical CEPC-CQ8LA interface line processing unit A 100 Gbps (QSFP28,LC) 8-port 100G Ethernet optical CEPC-CQ8L1A interface line processing unit A 100 Gbps...
Page 92
(3) Card status LED. For the LED description, see Table2-167. LEDs Table2-166 QSFP-DD port LED description Status Description The QSFP-DD port is sending or receiving Flashing data. QSFP-DD port LED A link is present on the QSFP-DD port. No link is present on the QSFP-DD port. Table2-167 Card status LED description Status Description...
CEPC-XP24LX View Figure2-30 CEPC-XP24LX view (1) 10GBASE-R/W-SFP+ fiber ports (24 in total) (10GE SFP+ (2) SFP+ port LED. For the LED description, modules supported) see Table2-170. LEDs Table2-170 SFP+ port LED description Status Description The SFP+ port is sending or Flashing receiving data.
Item Description Power consumption (with typical 289 W configuration) Minimum power 237.6 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature CEPC-XP48RX View Figure2-31 CEPC-XP48RX view (2) SFP+ port LED. For the LED description, see (1) 10GBASE-R-SFP+ fiber ports (48 in total) Table2-173.
Technical specifications Table2-175 Technical specifications Item Description Dimensions (H × W × 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) Weight 4.75 kg (10.47 lb) Maximum power 407 W consumption Power consumption (with typical 336 W configuration) Minimum power 234.8 W...
Ports Table2-177 Port specifications Port Connector Port Card model Description transmission type quantity speed 4-port 10GBASE-R/W Ethernet CEPC-XP4LX optical interface line processing 10 Gbps unit module (SFP+, LC) Technical specifications Table2-178 Technical specifications Item Description Dimensions (H × W × 40 ×...
Page 97
CR16010H-F CR16010H-F (with five (with four fabric fabric CR16010-F, modules), modules), CR16010H-FA, Card model CR16006-F CR16014-F CR16018-F CR16018-F CR16018-FA (with five (with four fabric fabric modules) modules) CEPC-CP4R Supported Supported Not supported Not supported supported CEPC-CP4R Not supported Not supported Not supported Supported supported...
Card model CR16005E-F CR16010E-F CEPC-DQ2L1-G Not supported Supported CSPEX base cards CSPEX-1104-E/CSPEX-1204/CSPEX-1304X/CSPEX-1404 X/CSPEX-1504X/CSPEX-1504XA IMPORTANT: A CSPEX-1104-E card supports a maximum of three MIC-XP4L1 and MIC-GP4L subcards in total. View Figure2-33 CSPEX-1204 view (1) Card status LED. For the LED description, see Table2-181. The views of CSPEX-1204, CSPEX-1304X, CSPEX-1404X, CSPEX-1504X, CSPEX-1504XA, and CSPEX-1104-E are similar.
Technical specifications Table2-183 Technical specifications Item Description Dimensions (H × W × 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) • CSPEX-1104-E: 3.45 kg (7.61 lb) • CSPEX-1204: 3.50 kg (7.72 lb) • CSPEX-1304X: 3.75 kg (8.27 lb) Weight •...
Page 100
Status Description Steady on The card is faulty. The card is faulty or is not in position. Flashing (about once per RUN (Green) The card is operating correctly. second) Fast flashing (about eight The card is starting up. If the LED keeps fast flashing, times per second) card registration has failed.
Page 101
Figure2-35 CSPEX-1512X view (1) Card status LED. For the LED description, see Table2-187. The views of the CSPEX-1512X, CSPEX-1612X, CSPEX-1812X, CSPEX-1812X-E, CSPEX-1802X, CSPEX-1802XA, and CSPEX-2612XA are similar. This figure uses the CSPEX-1512X as an example. LEDs Table2-187 LED description Status Description Steady on The card is faulty.
Item Description (19.84 lb) • CSPEX-1512X: 281 W • CSPEX-1612X: 320 W Maximum power • CSPEX-1812X: 657 W consumption • CSPEX-1812X-E, CSPEX-1802X, CSPEX-1802XA: 486 W • CSPEX-2612XA: 538 W • CSPEX-1512X: 202 W • CSPEX-1612X: 238 W Power consumption • CSPEX-1812X: 426 W (with typical •...
Card model Number of subcard slots CSPEX-1804X Technical specifications Table2-192 Technical specifications Item Description Dimensions (H × W × 52.5 × 399 × 352 mm (2.07 × 15.71 × 13.86 in) Weight 6.30 kg (13.89 lb) Maximum power 625 W consumption Power consumption 510 W...
Card model Number of subcard slots CSPEX-2304X-G Technical specifications Table2-195 Technical specifications Item Description Dimensions (H × W × 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) Weight 4.65 kg (10.25 lb) Maximum power 280 W consumption Power consumption (with typical...
Table2-197 Subcard slots Card model Number of subcard slots CSPEX-2304X-LG Technical specifications Table2-198 Technical specifications Item Description Dimensions (H × W × 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) Weight 4.65 kg (10.25 lb) Maximum power 280 W consumption Power consumption...
Subcard slots Table2-200 Subcard slots Card model Number of subcard slots CSPEX-2612X3A Technical specifications Table2-201 Technical specifications Item Description Dimensions (H × W × 52.5 × 399 × 352 mm (2.07 × 15.71 × 13.86 in) Weight 9.00 kg (19.84 lb) Maximum power 538 W consumption...
Page 107
CR16010H-F CR16010H-F (with five (with four fabric fabric CR16010 Card modules), modules), H-FA, CR16006-F CR16010-F CR16014-F model CR16018-F CR16018-F CR16018- (with five (with four fabric fabric modules) modules) CSPEX- Supported Supported Supported Supported Not supported 1304X supported CSPEX- Supported Supported Supported Supported Not supported...
Page 108
Table2-203 Compatibility matrix between CSPEX cards and routers (2) Card model CR16005E-F CR16010E-F CSPEX-1204 Not supported Not supported CSPEX-1104-E Not supported Not supported CSPEX-1304X Supported Supported CSPEX-1404X Supported Supported CSPEX-1504X Supported Supported CSPEX-1504XA Not supported Not supported CSPEX-1502X Not supported Not supported CSPEX-1502XA Not supported...
Page 109
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 and 2: support and 2: support support support support support support Support Support Slots 3 Slots 3 and 4: and 4: support...
Page 110
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 and 4: and 4: support support MIC-GT20 support support support support support support support support support Slots 1 and 2: Support...
Page 111
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 Support Slots 1 and 2: support MIC-GP10 support support support support support support support support Slots 3 and 4: Support MIC-GP10...
Page 112
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 Support Support MIC-XP5L support support support support support support support MIC-XP5L Support Support support support support support support support...
Page 113
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 Slots 1 and 2: Support MIC-CQ1L support support support support support support support support Slots 3 and 4: support Slots 1...
Page 114
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 NIC-GP24 support support support support support support support support support NIC-GP24 Support support support support support support support support...
Page 115
CSPEX cards CSPE X-150 Subcard CSPE CSPE CSPE CSPE CSPE CSPE CSPE CSPE model X-120 X-130 X-150 X-150 X-150 X-160 X-160 X-180 CSPE X-140 P10L support support support support support support support support support RX-NIC-X support support support support support support support support...
Configuration restrictions and guidelines The subslot restrictions of a CMPE card depend on the subslot mode. For more information about subslot modes, see device management configuration in H3C CR16000-F Routers Fundamentals Configuration Guide. Compatibility information Table2-209 Compatibility matrix between CMPE cards and routers...
Page 123
Subcard model CMPE cards PIC-TCP8L Not supported PIC-PSP4L Not supported PIC-PS2G4L Not supported PIC-PUP1L Not supported PIC-XP1L Not supported MIC-GT20L Not supported MIC-GT20L1 Not supported MIC-GT20LA Not supported MIC-CLP4L Supported MIC-ET16L Supported MIC-CLP2L Supported Only one is supported. MIC-SP8L Can be installed only slot 1 or slot 2. MIC-SP4L Supported MIC-GP4L...
Subcard model CMPE cards MIC-CP2L-V2 Not supported MIC-CQ1L1 Not supported MIC-CQ1L2 Not supported MIC-CQ1LF Not supported MIC-CQ2L Not supported MIC-CQ2LA Not supported MIC-PSP4L Not supported MIC-TCP8L Not supported MIC-SEC Not supported NIC-GT20L Not supported NIC-GP20L Not supported NIC-GP24L Not supported NIC-GP24L1 Not supported NIC-GP24L1A...
RX-SPE200/RX-SPE200-E View Figure2-41 RX-SPE200 view (1) Card status LED. For the LED description, see Table2-211. The views of the RX-SPE200 and RX-SPE200-E are similar. This figure uses the RX-SPE200 as an example. LEDs Table2-211 LED description Status Description Steady on The card is faulty.
Item Description • consumption RX-SPE200-E: 120 W Operating 0°C to 45°C (32°F to 113°F) temperature Compatibility information Table2-214 Compatibility matrix between SPE cards and routers CR16010H-F CR16010H-F (with five (with four fabric fabric CR16006-F, CR16010H-F Card modules), modules), CR16005E-F, CR16010-F, model CR16018-F CR16018-F...
Page 127
Subcard model RX-SPE200 RX-SPE200-E MIC-GP10LA Not supported Not supported MIC-GP20L Not supported Not supported MIC-GP20L1 Not supported Not supported MIC-XP2L Not supported Not supported MIC-XP2L-LAN Not supported Not supported MIC-XP4L1 Not supported Not supported MIC-XP5L Not supported Not supported MIC-XP5L1 Not supported Not supported MIC-XP5L2...
Subcard model RX-SPE200 RX-SPE200-E NIC-CC1L Not supported Not supported NIC-CC2L Not supported Not supported NIC-CQ1L Supported Not supported NIC-CQ2L Not supported Not supported NIC-CQ2LA Not supported Not supported RX-NIC-GP20L Supported Not supported RX-NIC-XP5L Supported Supported RX-NIC-XP10L Supported Supported RX-NIC-XP20L Not supported Not supported RX-NIC-YGS4L Supported...
Page 129
Figure2-42 MIC-CLP2L view (2) Port LED. For the LED description, see (1) CPOS-OC3/STM1-SFP ports (2 in total) Table2-216. LEDs Table2-216 WAN port LED description Status Description The port is up and is receiving or sending data Flashing green correctly. The port is up and no services are running on the WAN port LED Steady green port.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature MIC-CLP4L View Figure2-43 MIC-CLP4L view (2) Port LED. For the LED description, see (1) CPOS-OC3/STM1-SFP ports (4 in total) Table2-219. LEDs Table2-219 WAN port LED description Status Description The port is up and is receiving or sending data Flashing green correctly.
Item Description Weight 0.30 kg (0.66 lb) Maximum power 12.9 W consumption Minimum power 9.8 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature MIC-CP1L View Figure2-44 MIC-CP1L view (2) CFP port LED. For the LED description, see (1) 100GBASE-R-CFP fiber port (1 in total) Table2-222 LEDs Table2-222 CFP port LED description...
Port Connector Port Card model Description transmission type quantity speed interface card (CFP, LC) Technical specifications Table2-224 Technical specifications Item Description Dimensions (H × W × 37 × 171 × 157 mm (1.46 × 6.73 × 6.18 in) Weight 0.55 kg (1.21 lb) Maximum power 11.8 W consumption...
Status Description The QSFP28 port is sending or receiving Flashing data at 100 Gbps. QSFP28 port LED A 100 Gbps link is present on the QSFP28 Steady on port. No link is present on the QSFP28 port. Ports Table2-235 Port specifications Port Connecto Port...
Table2-237 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving Flashing data at 100 Gbps. QSFP28 port LED A 100 Gbps link is present on the QSFP28 Steady on port. No link is present on the QSFP28 port. Ports Table2-238 Port specifications Port...
see Table2-240. LEDs Table2-240 Fiber port LED description Status Description Flashing The port is sending or receiving data. Fiber port LED Steady on A link is present on the port. No link is present on the port. Ports Table2-241 Port specifications Port Connector Port...
Table2-243. LEDs Table2-243 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving Flashing data at 100 Gbps. QSFP28 port LED A 100 Gbps link is present on the QSFP28 Steady on port. No link is present on the QSFP28 port. Ports Table2-244 Port specifications Port...
Page 140
Figure2-52 MIC-ET16L view (2) Port LED. For the LED description, see (1) E1-HM96 copper ports (16 in total) Table2-246. Table2-246 LED description Status Description Flashing green The port is sending or receiving data. Steady green A link is present, but the port is not receiving or sending data. ACT/ALM Steady red An alarm has occurred.
Item Description temperature MIC-GP10L1/MIC-GP10L2 View Figure2-53 MIC-GP10L1 view (2) SFP port LED. For the LED description, see (1) 1000BASE-X-SFP fiber ports (10 in total) Table2-249. The views of the MIC-GP10L1 and MIC-GP10L2 are similar. This figure uses the MIC-GP10L1 as an example.
Table2-255. LEDs Table2-255 GE SFP port LED description Status Description The SFP port is sending or receiving Flashing green data. GE SFP port LED (LINK/ACT) Green A link is present on the SFP port. No link is present on the SFP port. Ports Table2-256 Port specifications Port...
Page 145
Figure2-56 MIC-GP20L1 view (2) SFP port LED. For the LED description, see (1) 1000BASE-X-SFP fiber ports (20 in total) Table2-258. LEDs Table2-258 GE SFP port LED description Status Description The SFP port is sending or receiving Flashing green data. GE SFP port LED (LINK/ACT) Green A link is present on the SFP port.
Item Description temperature MIC-GP4L View Table2-261 MIC-GP4L view (2) Combo fiber port LINK/ACT LED. For the LED (1) Combo interfaces (4 in total) description, see Table2-262. (3) Combo copper LINK LED. For the LED (4) Combo copper ACT LED. For the LED description, description, see Table2-262.
Status Description Green A link is present on the SFP port. No link is present on the SFP port. Ports Table2-266 Port specifications Port Connecto Port Card model Description transmission r type quantity speed 100 Mbps 8-port 1000BASE-X optical MIC-GP8L 1000 Mbps interface card (SFP, LC) 10/100/1000 Mbps...
Page 149
Figure2-58 MIC-GT20L view (2) RJ-45 Ethernet port LED. For the description for the RJ-45 port LEDs on the MIC-GT20L and MIC-GT20LA, (1) 10/100/1000BASE-T copper ports (20 in total) see Table2-268. For the description for the RJ-45 port LEDs on the MIC-GT20L1, see Table2-269. The views of the MIC-GT20L, MIC-GT20L1, and MIC-GT20LA are similar.
Status Description The port is up and is receiving or sending data Flashing green correctly. The port is up and no services are running on the WAN port LED Steady green port. (ACT/ALM) Steady red An alarm has occurred. The port is down. Ports Table2-273 Port specifications Port...
Table2-275 QSFP+ port LED description Status Description The QSFP+ port is sending or Flashing receiving data. A link is present on the QSFP+ QSFP+ port LED Steady on port. No link is present on the QSFP+ port. Ports Table2-276 Port specifications Port Connecto Port...
Page 153
Figure2-61 MIC-SP4L view (1) OC-3c/STM-1c POS/ATM fiber ports (4 in total) (2) Port LED. For the LED description, see or OC-12c/STM-4c POS/ATM fiber ports (port 1) Table2-278. LEDs Table2-278 WAN port LED description Status Description The port is up and is receiving or sending data Flashing green correctly.
Item Description consumption Minimum power 9.6 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature MIC-SP8L View Figure2-62 MIC-SP8L view (2) Port LED. For the LED description, see (1) OC-3c/STM-1c POS fiber ports (8 in total) Table2-281. LEDs Table2-281 WAN port LED description Status Description The port is up and is receiving or sending data...
Item Description Dimensions (H × W × 18 × 171 × 157 mm (0.71 × 6.73 × 6.18 in) Weight 0.30 kg (0.66 lb) Maximum power 16.3 W consumption Minimum power 14 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature MIC-TCP8L View...
Status Description No link is present on the port. NOTE: You can identify the speed of a port by observing the color of its LED. Green indicates a speed of 25 Gbps, and yellow indicates a speed of 10 Gbps. Ports Table2-288 Port specifications Port...
LEDs Table2-290 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port. NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps.
Page 159
Figure2-66 MIC-XP20L view (1) 10GBASE-R/W-SFP+ fiber ports (20 in total) (10GE (2) SFP+ port LED. For the LED description, SFP+ modules supported) see Table2-293. The views of MIC-XP20L and MIC-XP20LA are similar. This figure uses the MIC-XP20L as an example. LEDs Table2-293 SFP+ port LED description Status...
Port Connecto Port Card model Description transmission r type quantity speed A (SFP+, LC) 1000 Mbps 10 Gbps Technical specifications Table2-295 Technical specifications Item Description Dimensions (H × W × 38 × 179 × 149 mm (1.50 × 7.05 × 5.87 in) Weight 0.95 kg (2.09 lb) Maximum power...
NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps. Ports Table2-297 Port specifications Port Connecto Port Card model Description transmission r type...
LEDs Table2-299 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port. NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps.
Page 163
Figure2-69 MIC-XP4L1 view (2) SFP+ port LED. For the LED description, see (1) 10GBASE-R/W-SFP+ fiber ports (4 in total) Table2-302. LEDs Table2-302 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port.
Item Description consumption Minimum power 11 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature MIC-XP5L View Figure2-70 MIC-XP5L view (2) SFP+ port LED. For the LED description, see (1) 10GBASE-R/W-SFP+ fiber ports (5 in total) Table2-305. LEDs Table2-305 SFP+ port LED description Status Description The port is sending or receiving...
Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port. NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps.
Page 167
Figure2-72 MIC-XP8L view (2) SFP+ port LED. For the LED description, (1) 10GBASE-R/W-SFP+ fiber ports (8 in total) see Table2-311. LEDs Table2-311 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port.
Item Description Minimum power 16 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature NIC subcards IMPORTANT: • To use a NIC interface card, you must install it on a CMPE, SPE, or CSPEX base card. You cannot install it directly on the router. •...
Status Description The QSFP28 port is sending or receiving Flashing data at 100 Gbps. QSFP28 port LED A 100 Gbps link is present on the QSFP28 Steady on port. No link is present on the QSFP28 port. Ports Table2-321 Port specifications Port Connecto Port...
Page 172
Figure2-76 NIC-CQ2L view (2) QSFP28 port LED. For the LED description, see (1) 100GBASE-R-QSFP28 fiber ports (2 in total) Table2-323. The views of NIC-CQ2L and NIC-CQ2LA are similar. This figure uses the NIC-CQ2L as an example. LEDs Table2-323 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving...
Item Description Maximum power 26 W consumption Minimum power 16 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature NIC-GP20L View Figure2-77 NIC-GP20L view (2) SFP port LED. For the LED description, see (1) 1000BASE-X-SFP fiber ports (20 in total) Table2-326.
Item Description Dimensions (H × W × 47.5 × 179 × 118 mm (1.87 × 7.05 × 4.65 in) Weight 0.65 kg (1.43 lb) Maximum power 13.8 W consumption Minimum power 12 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature NIC-GP24L View...
Status Description Green A link is present on the SFP port. No link is present on the SFP port. Ports Table2-333 Port specifications Port Connecto Port Card model Description transmission r type quantity speed 100 Mbps 24-port 1000BASE-X Ethernet NIC-GP24L1 1000 Mbps optical interface card 10/100/1000 Mbps...
Page 177
Figure2-80 NIC-GT20L view (2) RJ-45 Ethernet port LED. For the LED (1) 10/100/1000BASE-T copper ports (20 in total) description, see Table2-335. LEDs Table2-335 RJ-45 Ethernet port LED description Status Description The port is sending or receiving Flashing data. RJ-45 Ethernet port LED Steady on A link is present on the port.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature NIC-XP10L View Figure2-81 NIC-XP10L view (2) SFP+ port LED. For the LED description, (1) 10GBASE-R/W-SFP+ fiber ports (10 in total) see Table2-338. LEDs Table2-338 SFP+ port LED description Status Description The port is sending or receiving Flashing data.
Item Description Dimensions (H × W × 47.5 × 179 × 118 mm (1.87 × 7.05 × 4.65 in) Weight 0.65 kg (1.43 lb) Maximum power 27.4 W consumption Minimum power 26.9 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature NIC-XP20L View...
Status Description No link is present on the port. NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps. Table2-345 GE SFP port LED description Status Description...
Page 182
Figure2-84 NIC-XP5L view (2) SFP+ port LED. For the LED description, see (1) 10GBASE-R/W-SFP+ fiber ports (5 in total) Table2-348. LEDs Table2-348 SFP+ port LED description Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature RX-NIC-CC1L View Figure2-85 RX-NIC-CC1L view (2) CFP2 port LED. For the LED description, see (1) 100GBASE-R-CFP2 fiber port (1 in total) Table2-351. LEDs Table2-351 CFP2 port LED description Status Description The CFP2 port is sending or receiving Flashing data at 100 Gbps.
Item Description Maximum power 9.7 W consumption Minimum power 9.6 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature RX-NIC-CC2L View Figure2-86 RX-NIC-CC2L view (2) CFP2 port LED. For the LED description, see (1) 100GBASE-R-CFP2 fiber ports (2 in total) Table2-354.
Item Description Dimensions (H × W × 47.5 × 179 × 118 mm (1.87 × 7.05 × 4.65 in) Weight 0.85 kg (1.87 lb) Maximum power 21 W consumption Minimum power 19.2 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature RX-NIC-CQ1LF View...
Status Description A 100 Gbps link is present on the QSFP28 Steady on port. No link is present on the QSFP28 port. NOTE: You can identify the speed of a QSFP28 port by observing the color of its LED. Green indicates a speed of 100 Gbps, and yellow indicates a speed of 50 Gbps.
Page 188
Figure2-89 RX-NIC-GP20L view (2) SFP port LED. For the LED description, see (1) 1000BASE-X-SFP fiber ports (20 in total) Table2-363. LEDs Table2-363 GE SFP port LED description Status Description The SFP port is sending or receiving Flashing green data. GE SFP port LED (LINK/ACT) Green A link is present on the SFP port.
RX-NIC-LGQ2L View Figure2-90 RX-NIC-LGQ2L view (2) QSFP28 port LED. For the LED (1) 50GBASE-R-QSFP28 fiber ports (2 in total) description, see Table2-366. LEDs Table2-366 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving Flashing data at 100 Gbps. A 100 Gbps link is present on the QSFP28 QSFP28 port LEDs Steady on...
Item Description consumption Minimum power 38 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature RX-NIC-LGQ4L View Figure2-91 RX-NIC-LGQ4L view (2) QSFP28 port LED. For the description, see (1) 50GBASE-R-QSFP28 fiber ports (4 in total) Table2-369. LEDs Table2-369 QSFP28 port LED description Status Description The QSFP28 port is sending or receiving...
Item Description Dimensions (H × W × 47.5 × 179 × 118 mm (1.87 × 7.05 × 4.65 in) Weight 0.90 kg (1.98 lb) Maximum power 92 W consumption Minimum power 55 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature RX-NIC-XP10L View...
You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps. Ports Table2-376 Port specifications Port Connecto Port Card model Description transmission r type...
Status Description The port is sending or receiving Flashing data. SFP+ port LED Steady on A link is present on the port. No link is present on the port. NOTE: You can identify the speed of an SFP+ port by observing the color of its LED. Green indicates a speed of 10 Gbps, and yellow indicates a speed of 1000 Mbps.
(1) 10GBASE-R-SFP+ ports or 25GBASE-R-SFP28 ports (2) SFP28 port LED. For the LED description, (4 in total) see Table2-381. LEDs Table2-381 SFP28 port LED description Status Description Flashing The port is sending or receiving data. SFP28 port LED Steady on A link is present on the port.
PIC-GP10L View Figure2-96 PIC-GP10L view (1) 1000BASE-X-SFP Ethernet fiber ports (10 (2) SFP port LED. For the LED description, see in total) Table2-384. LEDs Table2-384 GE SFP port LED description Status Description The SFP port is sending or receiving Flashing green data.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature PIC-PS2G4L View Figure2-97 PIC-PS2G4L view (1) OC48c/STM16c-SFP POS fiber ports (2 in total) (2) 1000BASE-X-SFP GE fiber ports (4 in total) (3) POS port LED. For the LED description, see (4) GE port LED.
Status Description No link is present on the XFP port. Ports Table2-401 Port specifications Port Connector Port Card model Description transmission type quantity speed 1-port 10GBASE-R/W PIC-XP1L Ethernet optical interface 10 Gbps card (XFP, LC) Technical specifications Table2-402 Technical specifications Item Description Dimensions (H ×...
LEDs Table2-403 LED description Mark Status Description The system is operating correctly. Alarm LED A critical fault has occurred to the system and Steady red the fault must be handled immediately. No power is input or the service module has failed.
Page 204
Figure2-103 IM-ACG1000X-IV view (1) Captive screw (2) Ejector lever (3) Drive slot (4) Console port (CONSOLE) (5) GE copper port (10/100/1000BASE-T) (6) USB port (7) Drive LED (HD) (8) System LED (SYS) LEDs Table2-406 LED description Mark Status Description Data is being read from or written to the Fast flashing green drive.
Item Description Operating 0°C to 45°C (32°F to 113°F) temperature IM-IPSX-IV View Figure2-104 IM-IPSX-IV view (1) Captive screw (2) Ejector lever (3) Drive slot (4) Console port (CONSOLE) (5) GE copper port (10/100/1000BASE-T) (6) USB port (7) Drive LED (HD) (8) System LED (SYS) LEDs Figure2-105 LED description...
Item Description Dimensions (H × W × 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) Weight 4.80 kg (10.58 lb) Maximum power 235 W consumption Minimum power 175 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature IM-NGFWX-IV View...
Mark Status Description Slow flashing The system is operating correctly. green (1 Hz) Fast flashing The system is loading software or has not green (8 Hz) started. No link is present. Combo interface LINK/ACT Steady green A link is present. Flashing green The interface is sending or receiving data.
Page 209
(3) Combo copper port (10/100/1000BASE-T) (4) Combo copper port LED (LINK/ACT) (5) Combo fiber port (1000BASE-X) (6) Combo fiber port LED (LINK/ACT) (7) Alarm LED (ALM) (8) System LED (RUN) (9) Ejector lever (10) Captive screw LEDs Table2-417 LED description Mark Status Description...
LSU3FWCEA0 View Figure2-109 LSU3FWCEA0 view 7 8 9 (1) Console port (CONSOLE) (2) USB port (reserved for future use) (3) Combo copper port (10/100/1000BASE-T) (4) Combo copper port LED (LINK/ACT) (5) Combo fiber port (1000BASE-X) (6) Combo fiber port LED (LINK/ACT) (7) Alarm LED (ALM) (8) System LED (RUN) (9) Ejector lever...
Technical specifications Table2-422 Technical specifications Item Description Dimensions (H × W × 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in) Weight 3.90 kg (8.60 lb) Maximum power 150 W consumption Minimum power 109 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature Configuration restrictions and guidelines...
View Figure2-110 IM-MSUX (1 U) view (1) Card status LED. For the LED description, see Table2-424. Table2-424 Card status LED description Status Description Steady on The card is faulty. The card is faulty or is not in position. RUN (Green) Flashing (about once The card is operating correctly.
Page 213
View Figure2-111 IM-MSUX (1.2 U) view (1) Card status LED. For the LED description, see Table2-427. LEDs Table2-427 Card status LED description Status Description Steady on The card is faulty. The card is faulty or is not in position. RUN (Green) Flashing (about once The card is operating correctly.
IM-MSEX-B NOTE: The IM-MSEX-B provides one subcard slot. You can use it without a subcard, or use it with an IM-SP-B for double CGN packet processing rate. View Figure2-112 IM-MSEX-B view (1) Card status LED. For the LED description, see Table2-430. LEDs Table2-430 Card status LED description Status...
Item Description Minimum power 248 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature IM-SP-B NOTE: The IM-SP-B must be installed on an IM-MSEX-B for use. It occupies one subcard slot and does not provide ports. View Figure2-113 IM-SP-B view (1) Card status LED.
Item Description Dimensions (H × W × 47.5 × 170 × 192 mm (1.87 × 6.69 × 7.56 in) Weight 1.20 kg (2.65 lb) Maximum power 130 W consumption Minimum power 95 W consumption Operating 0°C to 45°C (32°F to 113°F) temperature Configuration restrictions and guidelines For adequate ventilation and cooling, install the IM-MSUX (1U) card in the following slots only when...
Figure2-114 IM-SMUX view (1) Card status LED. For the LED description, see Table2-437. LEDs Table2-437 Card status LED description Status Description Steady on The card is faulty. The card is faulty or is not in position. RUN (Green) Flashing (about once The card is operating correctly.
Table2-440 Compatibility matrix between security monitor line processing units and routers CR16010H-F CR16010H-F (with five (with four fabric fabric CR16006-F, CR16010H-F Card modules), modules), CR16005E-F, CR16010-F, model CR16018-F CR16018-F CR16010E-F CR16014-F CR16018-FA (with five (with four fabric fabric modules) modules) IM-SMUX Not supported Supported...
Card model Description IM-SFMX Network data encryption service processing unit Technical specifications Table2-443 Technical specifications Item Description Dimensions (H × W × 40 × 399 × 355 mm (1.57 × 15.71 × 13.86 in) Weight 4.05 kg (8.93 lb) Maximum power 165 W consumption Power consumption...
• The MIC-SM is provided with six USB keys for you to obtain user roles to manage the card. To obtain a user role, first insert a USB key into USB port AUTH. For more information about the encryption card configuration, see encryption card user management in H3C CR16000-F Router Security Configuration Guide.
Table2-447 Port specifications Card model Description MIC-SM Network data encryption interface card Technical specifications Table2-448 Technical specifications Item Description Dimensions (H × W × 37 × 179 × 149 mm (1.46 × 7.05 × 5.87 in) Weight 0.90 kg (1.98 lb) Maximum power 40 W consumption...
Page 222
Figure2-3 IM-OAPX view Description Power on/standby button and system power LED 2.5 in SATA drive slot Drive Present/Active LED Drive Fault/UID LED BMC network port (1 Gb, RJ45) with default IP 192.168.1.2/24 Shared network port, which can be used as the following: •...
Page 223
Status Description Steady green The system is operating correctly. Flashing green (4 The BMC is currently resetting and initializing. Health LED Flashing yellow and A minor alarm occurs in the system, including an alarm on an error green (1 Hz) monitored by BMC or an alarm on hardware.
Page 224
Fault/UID Present/Active Description LED (green) (orange/blue) drive. The drive is not installed properly. Table2-455 BMC network port LED description Status Description Steady green The network port is being activated. BMC network port Flashing green (1 The network port is receiving or sending data. The network port is disconnected.
The console port on the panel of the universal open application platform is only for users. The internal console port of the universal open application platform is only for H3C Support to perform maintenance and updates. Operations without permission are not allowed. H3C will not be liable for any consequences caused thereby.
CSFC-04B/CSFC-04D View Figure2-5 CSFC-04B view (1) Switching fabric module status LED. For the LED (2) Console port description, see Table2-462. The views of CSFC-04B and CSFC-04D are similar. This figure uses the CSFC-04B as an example. LEDs Table2-462 Switching fabric module status LED description LED status Description Flashing (0.5...
CSFC-08B/CSFC-08D View Figure2-6 CSFC-08B view (2) Switching fabric module status LED. For the LED (1) Console port description, see Table2-464. The views of the CSFC-08B and CSFC-08D are similar. This figure uses the CSFC-08B as an example. LEDs Table2-464 Switching fabric module status LED description LED status Description Flashing (0.5...
CSFC-12B/CSFC-12D View Figure2-7 CSFC-12B view (2) Switching fabric module status LED. For the LED (1) Console port description, see Table2-466. The views of the CSFC-12B and CSFC-12D are similar. This figure uses the CSFC-12B as an example. LEDs Table2-466 Switching fabric module status LED description LED status Description Flashing (0.5...
CSFC-08E View Figure2-8 CSFC-08E view (1) Switching fabric module status LED. For the LED description, see Table2-468. LEDs Table2-468 Switching fabric module status LED description LED status Description Flashing (0.5 The switching fabric module is operating correctly. Steady on The switching fabric module is faulty. Flashing (0.5 The temperature of the switching fabric module has exceeded the upper limit Steady on...
CSFC-08E1/CSFC-08E1A/CSFC-08T View Figure2-9 CSFC-08E1 view (1) Switching fabric module status LED. For the LED description, see Table2-470. The views of the CSFC-08E1, CSFC-08E1A, and CSFC-08T are similar. This figure uses the CSFC-08E1 as an example. LEDs Table2-470 Switching fabric module status LED description RUN LED status Description Flashing (0.5 Hz)
CSFC-12E View Figure2-10 CSFC-12E view (1) Console port (2) Air inlet vents (3) Switching fabric module status LED. For the LED description, see Table2-472. LEDs Table2-472 Switching fabric module status LED description LED status Description Flashing (0.5 The switching fabric module is operating correctly. Steady on The switching fabric module is faulty.
CSFC-16T/CSFC-16T1/CSFC-16E/CSFC-16EA View Figure2-11 CSFC-16T1 view (1) Switching fabric module status LED. For the LED description, see Table2-474. The views of the CSFC-16T, CSFC-16T1, CSFC-16E, and CSFC-16EA are similar. This figure uses the CSFC-16T1 as an example. LEDs Table2-474 Switching fabric module status LED description RUN LED status Description Flashing (0.5 Hz)
CSFC-08T-G View Figure2-12 CSFC-08T-G view (1) Switching fabric module status LED. For the LED description, see Table2-476. LEDs Table2-476 Switching fabric module status LED description RUN LED status Description Flashing (0.5 Hz) The switching fabric module is operating correctly. Flashing (8 Hz) The switching fabric module is starting up.
CSFC-16T-G View Figure2-13 CSFC-16T-G view (1) Switching fabric module status LED. For the LED description, see Table2-478. LEDs Table2-478 Switching fabric module status LED description RUN LED status Description Flashing (0.5 Hz) The switching fabric module is operating correctly. Flashing (8 Hz) The switching fabric module is starting up.
CSFC-10T-G View Figure2-14 CSFC-10T-G view (1) Switching fabric module status LED. For the LED description, see Table2-480. LEDs Table2-480 Switching fabric module status LED description RUN LED status Description Flashing (0.5 Hz) The switching fabric module is operating correctly. Flashing (8 Hz) The switching fabric module is starting up.
CSFC-10E-G View Figure2-15 CSFC-10E-G view (1) Switching fabric module status LED. For the LED description, see Table2-482. LEDs Table2-482 Switching fabric module status LED description RUN LED status Description Flashing (0.5 Hz) The switching fabric module is operating correctly. Flashing (8 Hz) The switching fabric module is starting up.
• The console port on a switching fabric module is only for H3C Support to perform maintenance and updates. Operations without permission are not allowed. H3C will not be liable for any consequences caused thereby. • If Type-A switching fabric modules are used, use the four together and install each into the specified slot.
Page 240
Type-A Service module switching CSFC-04B CSFC-04D CSFC-08B CSFC-08D fabric module CSPEX-1504X Not supported Supported Supported Supported Supported CSPEX-1504XA Not supported Not supported Not supported Not supported Not supported CSPEX-1602X Not supported Not supported Not supported Not supported Not supported CSPEX-1602XA Not supported Not supported Not supported...
Page 241
Table2-486 Compatibility matrix between switching fabric modules and service modules (2) CSFC-12B Service module CSFC-08E CSFC-08E1 CSFC-08E1A CSFC-16EA CSFC-12D CSPC-GT48LA1 Supported Not supported Not supported Not supported supported CSPC-GE24L-E Supported Not supported Not supported Not supported supported CSPC-GP24LA1 Supported Not supported Not supported Not supported supported...
Page 242
CSFC-12B Service module CSFC-08E CSFC-08E1 CSFC-08E1A CSFC-16EA CSFC-12D CEPC-CQ8LA Not supported Supported Supported supported supported CEPC-CQ8L1A Not supported Supported Supported supported supported CEPC-CQ8L3A Not supported Supported Supported supported supported CEPC-CQ16L1 Not supported Not supported Not supported supported supported CEPC-DQ2L1-G Supported Not supported Not supported supported...
Page 243
CSFC-12B Service module CSFC-08E CSFC-08E1 CSFC-08E1A CSFC-16EA CSFC-12D CSPEX-1812X-E Supported Not supported Not supported supported supported CSPEX-2304X-G Supported Supported Not supported Not supported supported CSPEX-2304X-LG Supported Supported Not supported Not supported supported CSPEX-2612XA Not supported Supported Supported supported supported CSPEX-2612X3A Not supported Supported Supported...
CSFC-08 CSFC-10 CSFC-16 CSFC-12 CSFC-16 CSFC-08 CSFC-16 Service module CSFC-10 CSFC-16 supported supported supported supported IM-SMUX Supported Supported Supported Supported supported supported IM-SFMX Supported Supported supported supported supported supported IM-OAPX Supported Supported Supported Supported Supported supported Power supplies The router supports the PSR1200B-12A, PSR1200B-12A1-F, LSUM1AC2500, PSR2500-12A, LSUM1DC2400, PSR2400-12D, PSR2400-D, PSR2500B-12AHD-F, PSR1600B-12A-B, and PSR2000-12D-B power supplies.
Page 248
LED mark Status Description No power input. The input voltage is too low and the power supply has entered self-protection state. Steady green Power output of the power supply system is normal. Power output of the power supply system is abnormal. The power supply has an output short circuit, output overcurrent, output Steady red overvoltage, input undervoltage, or remote shutdown alarm and has...
PSR1200B-12A1-F View Figure2-17 PSR1200B-12A1-F power supply view (1) Captive screw (2) Power supply handle (3) Power input receptacle (4) Air inlet vent (5) Power output status LED (6) Power input status LED LEDs Table2-490 PSR1200B-12A1-F LED description LED mark Status Description Steady green The power supply system is operating correctly.
Item Description Rated input voltage 200 VAC to 240 VAC @ 50 Hz or 60 Hz range Input voltage range 180 VAC to 264 VAC Maximum input 10 A current Rated output voltage 12 VDC Rated output current 100 A Rated output power 1200 W Front-level circuit...
Page 251
LED mark Status Description self-protection state. Steady green Power output of the power supply system is normal. Power output of the power supply system is abnormal. The power supply has an output short circuit, output overcurrent, output Steady red overvoltage, input undervoltage, or remote shutdown alarm and has entered self-protection state.
PSR2400-12D/LSUM1DC2400 View Figure2-19 PSR2400-12D power supply view (1) Captive screw (2) Power supply handle (3) Power input status LED (4) Power output status LED (5) DC input negative terminal (–) (6) DC input positive terminal (+) The views of the PSR2400-12D and LSUM1DC2400 power supplies are similar. This figure uses the PSR2400-12D as an example.
Item Description Inputs Rated input voltage –48 VDC to –60 VDC range Input voltage range –36 V to –72 V Maximum input 78 A current Rated output voltage 12 VDC Rated output current 200 A Rated output power 2400 W Front-level circuit ≥...
LED mark Status Description Power output of the power supply system is abnormal. The power supply has an output short circuit, output overcurrent, output Steady red overvoltage, input undervoltage, or remote shutdown alarm and has entered self-protection state. An overtemperature alarm was triggered and the power supply has Steady amber entered self-protection state.
Page 255
(3) Power input receptacle (4) Power output status LED (5) Power input status LED (6) Air inlet vent LEDs Table2-498 PSR2500B-12AHD-F LED description LED mark Status Description Steady green The power supply system is operating correctly. No power input. The input voltage is too low and the power supply has entered self-protection state.
PSR1600B-12A-B View Figure2-22 PSR1600B-12A-B power supply view (1) Power supply handle (2) Power input receptacle (3) Latch (4) Power status LED LEDs Table2-500 PSR1600B-12A-B LED description LED status Description Steady green The power supply system is operating correctly. Flashing green The power supply has correct power input and is in standby state with 12 V standby (once per two output and without 12 V main output.
Item Description Weight 1.85 kg (4.08 lb) Inputs • 100 VAC to 240 VAC @ 50 Hz or 60 Hz Rated input voltage • range 240 VDC • 90 VAC to 305 VAC Input voltage range • 100 VDC to 240 VDC Maximum input 10 A current...
LEDs Table2-502 PSR2000-12D-B LED description LED status Description Steady green The power supply system is operating correctly. Flashing green The power supply is upgrading software. (once per second) Flashing green The power supply has correct power input and is in standby state with 12 V standby (once per two output and without 12 V main output.
output power of the installed power supplies is greater than the system power consumption. As a best practice, reserve 20% of the maximum output power. • Do not install power supplies of different models on the same router. • When the temperature of a power supply exceeds the upper limit or drops below the lower limit, the power supply shuts down automatically.
LEDs Table2-506 Fan tray LED description LED status Description FAIL Steady on The fan tray is operating correctly. Steady on The fan tray is faulty. The fan tray is not powered on. Technical specifications Table2-507 Technical specifications Item Description Dimensions (H × W × 106 ×...
LEDs Table2-508 Fan tray LED description LED status Description FAIL Steady on The fan tray is operating correctly. Steady on The fan tray is faulty. The fan tray is not powered on. Technical specifications Table2-509 Technical specifications Item Description Dimensions (H × W × 80 ×...
LEDs Table2-510 Fan tray LED description LED status Description FAIL Steady on The fan tray is operating correctly. Steady on The fan tray is faulty. The fan tray is not powered on. Technical specifications The CR16010-F (dual fan trays) has two fan trays, which are the same in technical specifications. Table2-511 describes the technical specifications of a single CR16010-F (dual fan trays) fan tray.
Page 264
View Figure2-27 CR16010H-F (with five fabric modules) fan tray view (1) Captive screw (2) Status LED (3) Fan tray handle (4) Fan The views of the CR16010H-F (with five fabric modules), CR16010H-F (with four fabric modules), CR16010H-FA, CR16018-F (with five fabric modules), CR16018-F (with four fabric modules), and CR16018-FA fan trays are similar.
Item Description (with typical configuration) Minimum power 18 W consumption Number of fans Fan diameter 80 mm (3.15 in) Max fan speed 12800 RPM Maximum air flow rate 350 CFM (9.91 m /min) CR16014-F fan tray View Figure2-28 CR16014-F fan tray view (1) Captive screw (2) Status LED (3) Fan tray handle...
Page 266
LED status Description FAIL The fan tray is not powered on. Technical specifications Table2-515 Technical specifications Item Description Dimensions (H × W × 84 × 301 × 646 mm (3.31 × 11.85 × 25.43 in) • Upper fan tray: 4.49 kg (9.90 lb) Weight •...
CR16005E-F fan tray View Figure2-29 CR16005E-F fan tray view (1) Status LED (2) Captive screw (3) Fan tray handle pivot (4) Fan tray handle (5) Fan LEDs Table2-516 Fan tray LED description RUN LED status Description Steady green The fan tray is operating correctly. Steady red One or more fans in the fan tray have failed or the fan tray is not in position.
Page 268
Item Description configuration) Minimum power consumption Number of fans Fan diameter 80 mm (3.15 in) Max fan speed 15200 RPM Maximum air flow rate 390 CFM (11.04 m /min) 2-239...
CR16010E-F fan tray View Figure2-30 CR16010E-F fan tray view (1) Captive screw (2) Status LED (3) Fan tray handle (4) Fan LEDs Table2-518 Fan tray LED description RUN LED status Description Steady green The fan tray is operating correctly. Steady red One or more fans in the fan tray have failed or the fan tray is not in position.
To prevent dusts from entering the chassis, you can configure air filters for the router as needed and install them at the air intakes. H3C CR16000-F air filters include the CR16006-F air filter, CR16010-F air filter, and CR16014-F air filter. Order air filters compatible with your router.
Item Description Maximum loading 200 kg (440.92 lb) capacity Adjustment range 380 to 630 mm (14.96 to 24.80 in) Occupied rack space 1 RU Configuration restrictions and guidelines • Select slide rails for the router based on the chassis weight. •...
15 m (49.21 ft) AC power cords AC power cords are used for connecting the AC power supplies of a CR16000-F router to the external AC power supply system. To select an AC power cord for an AC power supply, consider the following items: •...
Page 276
power cords conforms of power cords using this type of power cords to local safety regulations and can be used legally 04043396: 3 I type Mainland China m (9.8 ft) Plug outline Power cord outline Connector outline Countries or regions where the type of Countries or Other countries or...
Page 277
Holland, Denmark, Sweden, Finland, 0404A061: 3 Indonesia, Türkiye, F type Norway, Germany, m (9.8 ft) Russia, and CIS France, Austria, Belgium, and Italy Plug outline Power cord outline Connector outline Countries or regions where the type of Countries or Other countries or power cords conforms regions seldom Plug type...
Page 278
Countries or regions Countries or where the type of Other countries or Code power cords conforms regions seldom Plug type regions using this type (Length) to local safety using this type of of power cords regulations and can be power cords used legally 04041104: 3 I type...
Cable Ports connected Application Reference Console Console port at one end and 9-pin Connects the console port of the router See H3C cable serial port at the other end to the console terminal. SR8800-XCR 16000-F Router Series USB console port at one end and...
Figure 2 Straight-through cable white/orange orange white/green blue white/blue green white/brown brown Straight-through cable white/orange orange white/green blue white/blue green white/brown brown Figure 3 Crossover cable white/orange orange white/green blue white/blue green white/brown brown Crossover cable white/green green white/orange blue white/blue orange white/brown...
Table 3 RJ-45 MDI interface pinouts 10BASE-T/100BASE-TX 1000BASE-T Signal Function Signal Function Send data BIDA+ Bi-directional data cable A+ Send data BIDA- Bi-directional data cable A- Receive data BIDB+ Bi-directional data cable B+ Reserved BIDC+ Bi-directional data cable C+ Reserved BIDC- Bi-directional data cable C- Receive data...
Crimp the RJ-45 connector with the crimping pliers until you hear a click. Repeat the above steps with the other end of the cable. Use a cable tester to verify the proper connectivity of the cable. Optical fiber CAUTION: Use the same types of transceiver modules, pigtail cords, patch cords, and fiber cables. If you use single-mode optical fibers, the transceiver modules, pigtail cords, patch cords, and fiber cables must be single-mode.
VGA cable You can use a VGA cable to connect the universal open application platform and PC (or terminal). Figure 7 VGA cable Pos.15 Pos.15 Pos.1 Pos.1 Table 6 Cable connections between the universal open application platform and VGA connectors on the PC (or terminal) Singal VGA_RED VGA_GREEN...
Patch cords are mainly classified into SC, LC, and FC based on interface type. The typical length of a patch cord can be 0.5 m (1.64 ft), 1 m (3.28 ft), 2 m (6.56 ft), 3 m (9.84 ft), 5 m (16.40 ft), and 10 m (32.81 ft).
Page 289
• Never bend or curve a fiber when connecting it. After a fiber is installed correctly, the bend radius must be not less than 40 mm (the minimum dynamic bend radius is 20 D, and the minimum static bend radius is 10 D. D indicates the outer diameter of dust caps). •...
Need help?
Do you have a question about the CR16000-F and is the answer not in the manual?
Questions and answers