Thermo Scientific Dionex TCC-100 Operating Instructions Manual page 47

Thermostatted hplc column compartment
Table of Contents

Advertisement

Commands/
Properties
in Chromeleon
Disconnect
Door
EquilibrationTime
FirmwareVersion
GasLeak
GasLeakSensor
HardwareVersion
HumidityLeak
HumidityLeakSensor
Leak
LeakSensorState
MaxPosition
ModelNo
MsvPosition
Ready
ReadyTempDelta
SerialNo
TCC_INPUT_1
TCC_INPUT_2
TCC_RELAY_1
Description
Disconnects the column compartment from Chromeleon (also see
Connected, Connect).
Indicates whether the compartment door is open or closed (Open or
Closed; read-only).
Range: 0.0...30.0 min. Only if the deviation between the current
temperature and the set point specified under ReadyTempDelta does not
exceed the EquilibrationTime, the column compartment enters the Ready
state (also see ReadyTempDelta and Ready).
Indicates the compartment's firmware version (read-only).
Indicates whether the gas sensor has detected a leak
(Ok or Leak; read-only).
Sets the sensitivity with which the sensor responds to gas. Click the arrow
in the GasLeakSensor combo box and select the desired option from the
list: Low, Standard, or High. To turn the sensor off, select Off.
Indicates the compartment's hardware version (read-only).
Indicates whether the humidity sensor has detected a leak
(Ok or Leak; read-only).
Sets the sensitivity with which the sensor responds to humidity. Click the
arrow in the HumidityLeakSensor combo box and select the desired
option from the list: Low, Standard, or High.
To turn the sensor off, select Off.
Indicates whether at least one leak sensor has detected a leak (Ok or Leak;
read-only; also see HumidityLeak, GasLeak).
Indicates whether the sensors are ready for leak detection (Ready,
NotReady, Error; read-only).
If a column switching valve is installed and the Internal MSV check box is
selected on the Configuration tab page in the Server Configuration
program (→ page 38), the maximum number of positions of the installed
valve is indicated (read-only).
Indicates the device type (read-only).
If a column switching valve is installed and the Internal MSV check box is
selected on the Configuration tab page in the Server Configuration
program (→ page 38), the valve is switched to the desired position (A (1) or
B (2)).
Indicates whether the compartment is ready to operate (Ready or
NotReady; read-only; also see ReadyTempDelta and
EquilibrationTime).
Range: 0.0...5.0°C. If the current temperature deviates from the temperature
set point by more than the ReadyTempDelta, the column compartment
enters the NotReady state. If the ReadyTempDelta is set to '0', the system
does not check whether the temperature set point deviates from the actual
temperature (also see Ready and EquilibrationTime).
Indicates the serial number of the column compartment (read-only).
Indicates the state of digital input 1 (On or Off).
Indicates the state of digital input 2 (On or Off).
Relay 1. Click the "+ "character beside the relay name to display the items
underneath:
State−indicates the state of the relay.
Duration−when set, the relay toggles after the specified time.
On−turns the relay on.
Off−turns the relay off.
41
TCC-100 Operating Instructions