Signet Charger Operation, Model Hbs Series; Lestronic Ii ® Charger Operation - Taylor-Dunn ET-3000 Manual

Hide thumbs Also See for ET-3000:
Table of Contents

Advertisement

T-48 AC / ET 3000

Signet Charger Operation, Model HBS series

The Signet
HBS series chargers are fully automatic. The charger will turn itself ON when the AC power
®
cord is connected to the AC power source and turn itself OFF when the batteries are fully charged. Once
the charge cycle is complete, the charger will continue to monitor the batteries. If the battery voltage drops
during storage, the charger will start a new cycle to keep the batteries fully charged.
Note: If the charger restarts during a short time period of storage, then it would be an indication of
faulty batteries.
Refer to the data plate on the charger for the voltage and type
power required for the charger.
There is a series of LED's on the faceplate of the charger that
serve two functions:
1: Status of charge. The STATUS LED's will display an
approximate percent of charge during the charging cycle.
Refer to the table below.
2: Error condition. The FAULT LED flashing is an indication of a charging problem (charger may also
be beeping). Refer to the Charger Troubleshooting section for information on error codes.
Lestronic II
Charger Operation
®
The Lestronic II
charger is a semiautomatic charging system. The charger will
®
turn itself ON when the AC power cord is connected to the AC power source
and turn itself OFF when the batteries are fully charged. Refer to the data
plate on the charger for the voltage and type power required for the charger.
When the charger is plugged in, it should turn on within a few seconds. To
determine if the charger is on, listen for a humming sound from the charger. If
the charger does not turn on, then there may be a fault in the AC line voltage
or in the charger. Refer troubleshooting to a qualified technician.
Typical charging times are eight to twelve hours depending on the how deep the
batteries are discharged. Charging times exceeding 16-hours may be a result of faulty batteries, faulty charger,
noisy or fluctuating AC line voltage, or momentarily interrupting the charging cycle. Refer troubleshooting
to a qualified technician.