Taylor-Dunn ET-3000 Manual page 29

Hide thumbs Also See for ET-3000:
Table of Contents

Advertisement

T-48 AC / ET 3000
72-volt equipped with 30:1 drive ratio
Acceleration Parameters (normal mode)
Function
FwdAS LS
FwdAc HS
RevAc LS
RevAc HS
Acceleration Parameters (low speed mode)
FwdAS LS
FwdAc HS
RevAc LS
RevAc HS
Deceleration Settings
Brake Multiplier
Normal Decl HS
Normal Decl LS
Tow Decl HS
Tow Decl LS
Maintenance Meter Function
Service Timer
Speed Limits
Max (see warning)
Tow
Rev
Low Batt
Service Due
Battery Characteristics
Full Volts
Empty Volts
BDI Level for Batt Spd
BDI Reset %
Reset Volts
Discharge Time
Miscellaneous
SRO Min Speed
MB-T48-02
Safety Rules and Operating Instructions
Value
Unit Description
Time to accelerate to ~15% of full
3.2
S
speed
3.2
S
Time to accelerate to full speed
Time to accelerate to from FwdAC LS
5.2
S
to full
5.2
S
Time to accelerate to full speed
Time to accelerate to ~15% of full
4.0
S
speed
4.0
S
Time to accelerate to full speed
Time to accelerate to from FwdAC LS
5.0
S
to full
7.4
S
Time to accelerate to full speed
Brake regen multiplier is activated by
50
%
the brake switch
Time to decelerate to 0 when above
8.0
S
20% of full speed
Time to decelerate when below 20% of
8.0
S
full speed
Time to decelerate to 0 when above
9.5
S
20% of full speed
Time to decelerate when below 20% of
11.0
S
full speed
Refer to Maintenance Meter supple-
0
H
mentary manual
5,900
RPM Governed speed (see formula)
Percentage of Max speed when Tow
50
%
Switch is ON
Percentage of Max speed when in
50
%
reverse
Percentage of Max speed when low
40
%
battery warning is ON
Percentage of Max speed when service
25
%
is due. See maintenance Meter Function
Battery must exceed this voltage to be
2.165
V
considered fully charged
1.730
V
Voltage of a fully discharged battery
Low battery warning is ON when bat-
15
%
tery is discharged below this level
Battery must be discharged below this
80
%
value before the BDI will be allowed
to reset
Battery voltage must be above this
value to reset the BDI. Modified by the
2.1
V
'BDI Reset %' above)
60
M
Estimated battery discharge rate
Motor must be below this RPM to
2,000
RPM
change directions with the throttle pedal
depressed
Page 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-4B0-t48-48acB0-t48-72acEt-030-48ac

Table of Contents