SAFETY RULES AND OPERATING INSTRUCTIONS

CHARGING YOUR VEHICLE

Explosive mixtures of Hydrogen gas are
present within battery cells at all times. Do
not work with or charge battery in an area
where open flames (including gas furnace
or water heater pilots), sparks, cigarettes,
or any other sources of combustion are
present. Always provide ample ventilation
in rooms where batteries are being
charged. Failure to do so may result in
severe bodily injury and/or property
damage.

New Battery Break in

New batteries require a break in period of up to 40-cycles.
The batteries will not have their full capacity during this
break in period and may require longer charging times.
Signet
®
Charger Operation
The Signet
HB-600 and
®
HB-1000 chargers use a
semi-automatic charging
system. The charger will turn
itself ON when the AC power
cord is connected to the AC
power source and turn itself
OFF when the batteries are
fully charged. Refer to the data plate on the charger for
the voltage and type power required for the charger.
There is a series of LED's on the faceplate of the charger
that serve two functions:
1. Status of charge. The LED's will display an
approximate percent of charge during the charging
cycle. Refer to the table below.
2. Error condition. All three
LED's flashing is an
indication of a charging
problem (charger will also
be beeping). Refer to the
Charger Troubleshooting
section for information on
error codes.
LED1
Charging State
0 to 50%
Blinking
50% to 75%
ON
75% to 100%
ON
Cycle complete
ON
Safety Rules
Page 10
Typical Signet
®
Built In
LED2
LED3
OFF
OFF
Blinking
OFF
ON
Blinking
ON
ON
Battery electrolyte is poisonous and
dangerous. It contains sulfuric acid. Avoid
contact with skin eyes or clothing. Wear
rubber gloves and safety glasses while
servicing batteries. DO NOT INGEST! This
may result in severe bodily injury.
The key switch must be in the "OFF"
position when charging the batteries.
Failure to turn the key switch "OFF" may
result in damage to the vehicles electrical
system.
®
Lestronic II
Charger Operation
The Lestronic II
charger is a semi-automatic charging
®
system. The charger will turn itself ON when the AC
power cord is connected to the AC power source and
turn itself OFF when the batteries are fully charged. Refer
to the data plate on the charger for the voltage and type
power required for the charger. When plugged in, the
charger assumes that the batteries require charging and
will charger for a minimum of approximately 4-hours.
This charger should not be plugged in until the batteries
are discharged beyond 50% or the batteries may be
overcharged..
Typical Lestronic II
Charger

Industrial Charger Operation

The charger supplied with this vehicle is either specified
by or provided by the end user. Refer to the operating
instruction supplied with your charger or contact the
charger manufacturer for more information.
®