Taylor-Dunn ET-3000 Manual page 28

Hide thumbs Also See for ET-3000:
Table of Contents

Advertisement

Safety Rules and Operating Instructions
72-volt equipped with 24:1 drive ratio
Acceleration Parameters (normal mode)
Function
Value Unit Description
FwdAS LS
3.2
FwdAc HS
3.2
RevAc LS
5.2
RevAc HS
5.2
Acceleration Parameters (low speed mode)
FwdAS LS
4.0
4.0
FwdAc HS
RevAc LS
5.0
RevAc HS
7.4
Deceleration Settings
Brake Multiplier
50
8.0
Normal Decl HS
Normal Decl LS
8.0
Tow Decl HS
7.0
7.0
Tow Decl LS
Maintenance Meter Function
Service Timer
0
Speed Limits
Max (see warning)
5,900 RPM Governed speed (see formula)
Tow
43
Rev
43
Low Batt
40
Service Due
25
Battery Characteristics
Full Volts
2.165
Empty Volts
1.173
BDI Level for Batt Spd
15
BDI Reset %
80
2.1
Reset Volts
Discharge Time
60
Miscellaneous
SRO Min Speed
1,500 RPM
Page 14
Time to accelerate to ~15% of full
S
speed
S
Time to accelerate to full speed
Time to accelerate to from FwdAC
S
LS to full
S
Time to accelerate to full speed
Time to accelerate to ~15% of full
S
speed
S
Time to accelerate to full speed
Time to accelerate to from FwdAC
S
LS to full
S
Time to accelerate to full speed
% Brake regen multiplier is activated
by the brake switch
Time to decelerate to 0 when above
S
20% of full speed
Time to decelerate when below
S
20% of full speed
Time to decelerate to 0 when above
S
20% of full speed
Time to decelerate when below
S
20% of full speed
Refer to Maintenance Meter
H
supplementary manual
% Percentage of Max speed when
Tow Switch is ON
% Percentage of Max speed when in
reverse
% Percentage of Max speed when low
battery warning is ON
Percentage of Max speed when
%
service is due. See maintenance
Meter Function
V Battery must exceed this voltage to
be considered fully charged
V Voltage of a fully discharged bat-
tery
Low battery warning is ON when
%
battery is discharged below this
level
Battery must be discharged below
%
this value before the BDI will be
allowed to reset
Battery voltage must be above this
value to reset the BDI. Modified by
V
the 'BDI Reset %' above)
M Estimated battery discharge rate
Motor must be below this RPM to
change directions with the throttle
pedal depressed
48-volt equipped with 30:1 drive ratio
Acceleration Parameters (normal mode)
Function
Value Unit Description
FwdAS LS
2.6
FwdAc HS
4.0
RevAc LS
8.0
RevAc HS
7.0
Acceleration Parameters (low speed mode)
FwdAS LS
4.0
FwdAc HS
5.5
RevAc LS
8.0
RevAc HS
7.0
Deceleration Settings
Brake Multiplier
40
Normal Decl HS
8.0
Normal Decl LS
10.0
Tow Decl HS
8.5
Tow Decl LS
8.0
Maintenance Meter Function
Service Timer
0
Speed Limits
Max (see warning)
5,500 RPM Governed speed (see formula)
Tow
60
Rev
45
Low Batt
40
20
Service Due
Battery Characteristics
Full Volts
2.165
1.730
Empty Volts
BDI Level for Batt Spd
15
BDI Reset %
80
Reset Volts
2.1
Discharge Time
60
Miscellaneous
SRO Min Speed
1,500 RPM
T-48 AC / ET 3000
S Time to accelerate to ~15% of full
speed
S Time to accelerate to full speed
S Time to accelerate to from FwdAC
LS to full
S Time to accelerate to full speed
S Time to accelerate to ~15% of full
speed
S Time to accelerate to full speed
S Time to accelerate to from FwdAC
LS to full
S Time to accelerate to full speed
% Brake regen multiplier is activated
by the brake switch
S Time to decelerate to 0 when above
20% of full speed
S Time to decelerate when below
20% of full speed
S Time to decelerate to 0 when above
20% of full speed
S Time to decelerate when below
20% of full speed
Refer to Maintenance Meter
H
supplementary manual
% Percentage of Max speed when
Tow Switch is ON
% Percentage of Max speed when in
reverse
% Percentage of Max speed when low
battery warning is ON
Percentage of Max speed when
%
service is due. See maintenance
Meter Function
V Battery must exceed this voltage to
be considered fully charged
V Voltage of a fully discharged bat-
tery
Low battery warning is ON when
%
battery is discharged below this
level
Battery must be discharged below
%
this value before the BDI will be
allowed to reset
Battery voltage must be above this
value to reset the BDI. Modified by
V
the 'BDI Reset %' above)
M Estimated battery discharge rate
Motor must be below this RPM to
change directions with the throttle
pedal depressed
MB-T48-02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-4B0-t48-48acB0-t48-72acEt-030-48ac

Table of Contents