Scan Reversal
You will have to reverse the horizontal, vertical and convergence polarity when changing the projector's configuration.
To reverse the scan, proceed as follows:
CAUTION: Always disconnect the projector from the AC source before reversing the plug. Failure to observe this precaution may
result in electric shock or damage to the projector.
1 Open the top cover.
• See Opening Top Cover section.
2 Reverse the vertical and horizontal scan.
• To reverse the scan there are two sets of plugs on the sweep board. VR, VG and VB are the vertical connectors(V=vertical and
RGB=color) and HR, HG and HB are the horizontal connectors(H=horizontal and RGB=color).
Remove the plug and turn it 180 degrees, then reinstall. Do this for all three of either horizontal or vertical connectors depend-
ing upon your application (See Table below)
Horizontal and Vertical polarity
Connector pin
1 Lead
Setting
Blue
Ceiling front
Red
Desk top front
Red
Ceiling rear
Blue
Desk top rear
NOTE: The table is for non mirror applications.
HR, HG, HB
2 Lead
1 Lead
Red
Yellow
Blue
Brown
Blue
Yellow
Red
Brown
Yellow
Brown
Red
11
PROJECTION CONFIGURATION CHANGE
VR, VG, VB
2 Lead
Brown
Yellow
Brown
Yellow
Vertical polarity
connector
Blue
Horizontal polarity
connector