Connecting To An Uninterruptible Power Supply - Christie CP4445-RGB Installation And Setup Manual

Hide thumbs Also See for CP4445-RGB:
Table of Contents

Advertisement

5. Cut the Line (black or brown) and Neutral (white or blue) wires to shorten them to a length
between 80 to 100 mm.
6. Using a wire stripper, strip the insulation from each individual wire to expose 10 mm of bare
wire on the end.
7. Repeat steps 4 to 6 for the second line cord.
8. Pass the wires through the strain reliefs on each knockout plate and through the AC input
cover.
9. For each terminal block, fasten the bare end of the wires into the Ground (G), Line (L), and
Neutral (N) terminal connectors, starting first with the Ground (green) connection, followed by
the Line (black or brown) and Neutral (white or blue) connections.
10. Carefully lift the AC input cover into place, making sure the cover does not pinch any of the
wires.
11. Re-attach the cover using the six screws.
12. Using the eight screws, re-attach the two knockout plates and make sure the appropriate
strain relief is in place for each line cord.
13. Using the six screws, re-install the rear cover of the projector.

Connecting to an uninterruptible power supply

An uninterruptible power supply (UPS) allows the projector head electronics to remain operable during
a power failure.
Warning! If not avoided, the following could result in death or serious injury.
SHOCK HAZARD! The optional UPS power cord must be inserted into an outlet with grounding.
The UPS is connected through the 12V power supply on the projector. The following illustration shows
the power supply and connections.
CP4445-RGB and CP4455-RGB Installation and Setup Guide
020-103746-01 Rev. 1 (11-2022)
Copyright
©
2023 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Installing and setting up
31