2. Using the provided funnel, fill the chiller reservoir with the required coolant (Propylene Glycol
P/N: 163-130105-XX).
3. Start the chiller and allow the coolant lines to fill.
4. Check the coolant level in the reservoir and top up the coolant as required.
For detailed information on operating and maintaining the chiller, refer to the product
documentation provided by the chiller manufacturer.
5. Verify coolant is flowing in the correct direction and no leaks are in the system.
6. Make sure the chiller communication cable between the projector and the chiller is connected
correctly.
To avoid thermal shutdown conditions in dual projector installations, Christie recommends
running each chiller and its attached projector separately, with light on, to confirm chiller
communication cables are not cross-connected relative to the coolant lines.
Related information
Creating a new laser file for external chiller-based projectors (on page 72)

Maintaining the chiller

For detailed information on maintaining the chiller equipment, refer to the product documentation
provided by the chiller manufacturer.
To identify any leaks or problems, perform regular visual inspections of the chiller equipment and
connections to the projector.
CP4445-RGB and CP4455-RGB Installation and Setup Guide
020-103746-01 Rev. 1 (11-2022)