MultiVOIP Quick Start Guide
set the number of rings received on the FXO interface
before the MultiVOIP 200 answers the incoming call. The
default setting is 2 counts.
Note: Zero (0) means that the MultiVOIP 200 never
answers.
For FXO-to-FXO communications, you can enable a
specific type of FXO Disconnect; Current Loss, Tone
Detection, or Silence Detection. (Check with your in-
house phone personnel to verify the preferred type of
disconnect to use.) Enabling Tone Detection activates the
Disconnect Tone Sequence options. For Disconnect Tone
Sequence, you can select from drop-down lists either one
or two tones that will cause the line to be disconnected;
the person hanging up a call must then hit the key(s) that
will produce those tones. For Silence Detection, select
One Way or Two Way, then set the timer for the number of
seconds of silence before disconnect. Note that the default
value of 15 seconds may be shorter than desired for your
application.
E&M: If you are connecting to an analog E&M trunk on
your PBX, then choose the E&M interface option to enable
the E&M Options group. Check with your local in-house
phone personnel to determine if the signaling is Dial Tone
or Wink and if the connection is 2-wire or 4-wire. If Wink
signaling is used, then the Wink Timer is enabled with a
default of 250 milliseconds. The range of the Wink Timer is
from 100 to 350 milliseconds. Consult with your local in-
house phone personnel for this timer setting.
Note: After configuring a given channel (1 or 2), you can
copy that channel's configuration by clicking the Copy
button and everything on the Interface tab will be copied
to the other channel.