Operation Mode; Run Mode; Safe Mode - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

Section 6
Functions

Operation Mode

The Reader/Writer has two operation modes: Run Mode, and Safe Mode.
You can use the control signal to the Reader/Writer connector to change between these modes.

Run Mode

When you connect the control signal to the 24-VDC side of the power supply and turn ON the power
supply, the Reader/Writer will start in Run Mode.
Operation is performed in the modes specified in the commands from the host device and the results
are returned to the host device as responses.

Safe Mode

When you connect the control signal to the 0-VDC side of the power supply and turn ON the power
supply, the Reader/Writer will start in Safe Mode. The Safe Mode is used when you do not remember
the IP address that is set in the Reader/Writer. In Safe Mode, the Reader/Writer will start with the
following IP settings.
IP address: 192.168.1.200
Subnet mask: 255.255.255.0
RFID System
94
User's Manual
(PROFINET)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680 seriesV680s-hmd63-pntV680s seriesV680s-hmd66-pnt

Table of Contents