Section 2
System Configuration
The computer is connected to monitor the results of communications diagnostics
Reader/Writer
(V680S-HMD6 -PNT)
(V680 Series and V680S Series)
Connect the Ethernet Cable to a host device (e.g., Switching Hub or PLC) that supports STP and ground the host device to
100 Ω or less.
Always use a Switching Hub on any network where cyclic data exchanges are used.
RFID System
58
User's Manual
(PROFINET)
The system requires the combination of OS and browser to use
the Web browser.
For details, refer to Section 8 Web Browser Interface.
RF Tag
Ethernet Cable
Ethernet Cable (Max. length: 100 m)
(Recommended: XS5W-T42 - MC-K from OMRON)
Power Cable
(Recommended: XS5F-D42 - 80-F from OMRON)
p.189, p.191
Computer to monitor the
Host device
results of communications
(e.g., PLC)
diagnostics
Switching Hub
(Recommended: W4S1-05C Switching Hub
from OMRON)
24-VDC power supply
Computer