Measure Noise - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

MEASURE NOISE

This command measures the noise level around the Reader/Writer.
 Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
 Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespData/Response Data
Average Noise Level
Maximum Noise Level
Minimum Noise Level
 Execution Example
Measuring the Noise Level When the Average Level Is 51 (0033 Hex), the Maximum Level Is 62 (003E
ex), and the Minimum Level Is 41 (0029 Hex)
Command Area
Memory offset
Data name
Byte +0
+2
CmdCode
2
+4
CmdParam1
0
+6
CmdParam2
0
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
UINT
2 bytes
UINT
2 bytes
UINT
2 bytes
Byte +1
0
0
3
0
0
0
0
0
0
Host Communications Specifications
Function
2003 hex
0000 hex (Not used.)
0000 hex (Not used.)
Function
Error code
0000 hex (Not used.)
0000 hex (Not used.)
0000 to 0063 hex (level 0 to 99)
0000 to 0063 hex (level 0 to 99)
0000 to 0063 hex (level 0 to 99)
Response Area
Memory offset
Data name
Byte +0
+2
ErrCode
0
+4
RespInfo1
0
+6
RespInfo2
0
+8
RespData[0-1]
0
+10
RespData[2-3]
0
+12
RespData[4-5]
0
Section 7
Byte +1
0
0
0
0
0
0
0
0
0
0
3
3
0
3
E
0
2
9
RFID System
177
User's Manual
(PROFINET)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680 seriesV680s-hmd63-pntV680s seriesV680s-hmd66-pnt