Rf Analyzer - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

RF Analyzer

You can use the RF Analyzer to check the diagnostic information from communication diagnostic. You
can easily see whether communications are stable, unstable (warning), or in error when
communication diagnostic is used.
If communications are unstable (warning), you can display assumed causes and display guidance that
provides detailed cause confirmation and corrections.
If an error occurs, the error name and corrections are displayed.
When the Reader/Writer is running in safe mode, this screen can not be operated. Run the Reader/Writer in RUN
mode.
The diagnostic log is not displayed while communication diagnostic is disabled.
Enable communication diagnostic on the Communications Setting View.
If the number of records in the diagnostic log exceeds 2,048, the oldest records are overwritten.
Total number of records in diagnostic
log (2,048 max.), Number of unstable
communications, Number of errors
Click this button to refresh
the display.
Item name
No.
Time
Command
Result
UID
Diagnostic description
You can save the diagnostic log
in a CSV file on the computer.
Click this button to clear
the diagnostic log.
Numbers are assigned from 1 to 2,048.
The larger the number, the more recent the information.
The Reader/Writer operating time when the diagnostic information was registered.
The command that was executed when the diagnostics information was registered.
One of the following: Stable, Unstable (warning), or Error
Displays the UID of the RF Tags that were detected in communications diagnostics.
Displays the details of the communication diagnosis history.
No.
: Numbers are assigned from 1 to 2,048.
The larger the number, the more recent the information.
Command
: The command type that was executed when the diagnostic
information was registered.
Diagnostic description : The error code and assumed cause are displayed.
Signal Level
: Displays the signal level when communicating with the RF tag.
Noise
: Displays the noise level around the reader / writer during
communication with the RF tag.
Assumed cause/Correction: The assumed cause and corrections are displayed for unstable
(warning) communications and communications errors.
A button is displayed for unstable communications.Click the button and follow the displayed
guidance to display assumed causes and corrections.
Web Browser Interface
You can check the
diagnostic log on a graph.
This button is displayed when
diagnostic results show warning
communications.
Click the button to display guidance
in a separate window so that you
can check assumed causes and
corrections.
Description
Section 8
RFID System
201
User's Manual
(PROFINET)