Rf Tag Installation Precautions V680-D1Kp54T - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

RF Tag Installation Precautions
V680-D1KP54T
 Effect of Metal behind RF Tags
The communications range will decrease if there is metal at the back of the V680-D1KP54T RF Tag.
The V700-A80 Attachment is 8 mm thick. If the RF Tag is mounted on metallic material, use a non-
metallic spacer (e.g., plastic or resin). The following graphs show the relationship between the distance
from the RF Tag to the metallic surface and the communications range.
The V700-A80 Attachment is 8 mm thick.
V680S-HMD63-PNT and V680-D1KP54T
(%)
100
90
80
70
60
50
40
30
20
10
0
10
20
30
Distance (x) to the metal plate in back of RF Tag
Reader/Writer
Communications
range
Metal
Non-metallic material
V680S-HMD66-PNT and V680-D1KP54T
(%)
100
90
80
70
60
50
40
30
20
10
0
10
20
30
40
Distance (x) to the metal plate in back of RF Tag
Reader/Writer
Communications
range
Metal
Non-metallic material
40
50
60
70
80
90
100
110
(mm)
RF Tag
Metal on back
Y
X
50
60
70
80
90
100
110
(mm)
RF Tag
Metal on back
Y
X
V680S-HMD64-PNT and V680-D1KP54T
(%)
100
90
80
70
60
50
40
30
20
10
0
10
20
30
40
50
60
70
Distance (x) to the metal plate in back of RF Tag
Reader/Writer
RF Tag
Y
Communications
range
Metal
Non-metallic material
Section 11
Appendices
80
90
100
110
(mm)
Metal on back
X
RFID System
257
User's Manual
(PROFINET)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680 seriesV680s-hmd63-pntV680s seriesV680s-hmd66-pnt

Table of Contents