 Command Area
Offset
7
+0
Resv
+1
Resv
+2
+3
+4
+5
+6
+7
+8
:
+N
* Reserved (resv) bits are for future expansion. Do not turn them ON and OFF.
Signal/data
Name
EXE
Command Execution
Request
CmdCode
Command Code
CmdParam1
Command Parameter 1
CmdParam2
Command Parameter 2
CmdData
Command Data
PLC (IO Controller) ⇔ Reader/Writer (IO Device)
6
5
Resv
Resv
Resv
Resv
Resv
Resv
Command Parameter 1
Command Parameter 2
(The format depends on the command.)
Data type
Size
BOOL
1 bit
WORD
16 bits
WORD
16 bits
WORD
16 bits
---
---
Host Communications Specifications
Bit
4
3
2
Resv
Resv
Resv
Resv
Command Code
Command Data
Description
• Turn ON this bit to send a request to the Reader/Writer to
execute a command. Set the command code and parameters
before you turn ON this bit.
• You can turn OFF this bit during execution of a
communications command with RF Tags to cancel
communications processing by the Reader/Writer.
This word stores the command code.
These words store the command parameters.
Refer to the sections for individual commands for details.
These words store the command data.
Refer to the sections for individual commands for details.
Section 7
1
0
Resv
EXE
Resv
Resv
RFID System