Rf Tag Communications View - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

Section 8
Web Browser Interface

RF Tag Communications View

Select this check box to
repeatedly send the command.
1. Command Area
Item name
Command select
Data address
Data size
Write data
Repeat
2. Response Area
Item name
Error code/Diagnostics results
Number of communications
Command/Response Log
Clear
Refer to RFID System Maintenance in Section 6 Functions for details on communications diagnostics.
p.111
If RF Tag communications are attempted when the Reader/Writer is performing RF Tag communications, noise
measurement, or other processing, an error will occur. Perform operations when the Reader/Writer is not busy with
another operation.
RFID System
198
User's Manual
(PROFINET)
Description
Select the command to send.
Specify in 4-digit hexadecimal the first address to read or write
from the RF Tag.
Specify in 4-digit hexadecimal the number of words of data to
read from the RF Tag.
Specify the data to write to RF Tag.
Select this check box to repeatedly and consecutively send the
command. Clear the selection of this check box if the RF Tag
communications option of the Reader/Writer is set to Auto,
Repeat or FIFO Repeat. If a command is sent repeatedly and
consecutively with the Auto, Repeat or FIFO Repeat option, an
error dialog will occur.
The background will be green when the response returned by the Reader/Writer indicates a normal end.
If the response indicates an error end, the background will be red and the error code will be displayed.
If communications diagnostics are enabled and communications with the RF Tag are
determined to be unstable, the background will be yellow and the diagnostics result is
displayed.
The total number of commands that have been sent to the Reader/Writer is displayed.
Displays the sent command and write data, read data and the result.
[Cmd] : The send command is displayed. If the command is a data write, it is followed by <Write Data>.
[Res]
: Result of the response is displayed. If the response result is NG, the error details will be
displayed. If the ID read and data read are successful, <Read Data> follows the response result.
<Write Data> : The data to be written to the tag is displayed.
<Read Data> : The read data of the tag is displayed.
This button clears the number of sent commands and command/response log.
Click this button to send
the command.
Description
1
2
Setting range
ID READ / DATA READ
/ DATA WRITE
0000 to 0999 hex
0001 to 007D hex
1 to 113 words