System Connections Check Flowchart - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

System Connections Check Flowchart

START
No
Are the connector and
Cable connections OK?
Yes
Power ON
Connect them correctly.
RUN LED?
Lit green
NORM/ERR LED?
Check the control
signal line connection.
NORM/ERR LED?
Not lit
OK
Initialize the settings.
Flashing green
Flashing red
Not lit
Check the control
signal line connection.
Or initialize the settings.
Flashing red
Lit red
Replace the Reader/Writer.
Troubleshooting
Lit red
Replace the Reader/Writer.
Yes
Is the rated voltage
supplied?
No
Replace the Reader/Writer.
Supply the rated voltage.
Section 9
Not lit
RFID System
225
User's Manual
(PROFINET)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680 seriesV680s-hmd63-pntV680s seriesV680s-hmd66-pnt