Section 3
Component Names
 Operation Indicators
 RUN
Status
Lit green
Lighting while the Reader/Writer is in Run Mode and cyclic data exchanges connection are established.
Flashing
Flashes during operation in Safe Mode. (Flashes at 1-s intervals.)
green
Flashing
The indicator will flash quickly in the following cases. (Flashes at 200-ms intervals.)
green
• During Reader/Writer initialization
quickly
• While the Reader/Writer is in Run Mode and is waiting to establish a connection for cyclic data exchanges from the IO
controller
Lit yellow
Lights yellow while the Reader/Writer is operating in Slave Mode.
Flashing
Flashes quickly while the Reader/Writer is in Slave Mode and is waiting to establish a connection for cyclic data exchanges
yellow
from the IO controller.
quickly
Not lit
Turn off when power is not supplied.
 RF
Status
Lit yellow
Lighting during communication for RF Tag.
Not lit
Turn off when not in communication with no error.
 NORM/ERR
The NORM/ERR indicator shows the result of communications with an RF Tag.
Status
Lit green
Lights once when processing a communications command or another command from the host device is completed normally.
When communication diagnostic is enabled, this indicator will flash once each time a stable communication is detected.
Lit yellow
When communication diagnostic is enabled, this indicator will flash once each time an unstable communication is detected.
Flashing
Flashes quickly when a timeout is detected during cyclic data exchanges. (A timeout occurs when I/O data from the IO
yellow
controller is not received within the time specified for the timeout value.)
quickly
Lit red
Lights once when processing a communications command or another command from the host device ends in an error. It
continues to light if a system error occurred.
Flashing
Flash when recoverable error occurs. (Configuration memory error, or Control signal wiring mistake, etc.)
red
Flashing
The indicator will flash irregularly in the following cases. (It will repeatedly flash twice for 100 ms at 1-s intervals.)
red
• When the same IP address is detected for two different devices on the network at startup
irregularly
Not lit
Turn off when the standby state.
 LINK/ACT
Status
Lit
green
Lighting during linking normally.
Flashing
Flash during detects a carrier.
green
Not lit
Turn off when the Ethernet cable is not connected.
Refer to Errors and Indicator Status in Section 9 Troubleshooting for information of Error content of the operation indicator
p.216