Section 7
Host Communications Specifications

DATA FILL

This command fills the specified number of words in the RF Tag in the communications field with the
specified data.
 Command Area
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
CmdData/Command Data
Fill Data
 Response Area
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
 Execution Example
Writing 5A5A Hex to Four Words Starting from Word Address 1234 Hex in the RF Tag
Command Area
Memory offset
Data name
+2
CmdCode
+4
CmdParam1
+6
CmdParam2
+8
CmdData[0-1]
RFID System
162
User's Manual
(PROFINET)
Signal/data
Data type
WORD
WORD
WORD
ARRAY[]
OF BYTE
Signal/data
Data type
WORD
WORD
WORD
Byte +0
Byte +1
0
0
0
1
2
3
0
0
0
5
A
5
Size
2 bytes
0005 hex
First word address of the data to write to the RF Tag
2 bytes
0000 to FFFF hex
Number of words in the RF Tag to write
2 bytes
0000 hex: Specifies the entire area.
0001 to FFFF hex: Specified size
Fill data to write to the RF Tag (always one word)
2 bytes
Size
2 bytes
Error code
2 bytes
Device information
2 bytes
Communications diagnostics result
Response Area
Memory offset
5
+2
4
+4
4
+6
A
RF Tag Memory
User address
1234
hex
1235
hex
1236
hex
1235
hex
Function
Function
Data name
Byte +0
ErrCode
0
0
RespInfo1
0
0
RespInfo2
0
0
bit15-12 bit11-8
bit7-4
bit3-0
5
A
5
A
5
A
5
A
5
A
5
A
5
A
5
A
Byte +1
0
0
0
0
0
0

Advertisement