RF Tag Communications Errors

You can check errors detected by the Reader/Writer in the Response Area where the Reader/Writer
returns the response after command execution.
You can also check error information by sending the GET COMMAND ERROR LOG command to the
Reader/Writer or by using the Error Log View on a Web browser. The following table provides detailed
error information and countermeasures.
Error name
Error code
RF Tag missing error
RF Tag communications
error
UID mismatch error
RF Tag address error
RF Tag lock error
RF Tag verification error
RF Tag data lost error
RF Tag system error
RF Tag overwriting error
Reader/Writer connection
error
Communications connection
error between Reader/
Writers
2001 hex
Change the control timing so that communications start when there is an RF Tag in
the communications field of the Reader/Writer.
Measure the noise and implement noise countermeasures.
p.104
Check the influence of surrounding metal and make sure there is sufficient
communications range.
2002 hex
Change the control timing so that communications start when there is an RF Tag in
the communications field of the Reader/Writer.
Measure the noise and implement noise countermeasures.
p.104
Check the influence of surrounding metal and make sure there is sufficient
communications range.
2003 hex
Perform communications when the RF Tag for which data is to be restored is in the
communications field of the Reader/Writer.
2004 hex
Adjust the processing area (addresses) for communications with the RF Tag to
match the memory area of the RF Tag.
2005 hex
The RF Tag memory region that contains the communications processing area
(addresses) is locked.
Check the communications processing area (addresses) and perform the process
again or replace the RF Tag.
2006 hex
Repeat the processing while the RF Tag is in the communications field of the
Reader/Writer.
Measure the noise and implement noise countermeasures.
p.104
Check the influence of surrounding metal and make sure there is sufficient
communications range.
2007 hex
Repeat the processing while the RF Tag is in the communications field of the
Reader/Writer.
Measure the noise and implement noise countermeasures.
p.104
Check the influence of surrounding metal and make sure there is sufficient
communications range.
2008 hex
Change to an RF Tag that is supported by the Reader/Writer.
2009 hex
Replace the RF Tag.
200A hex
Make sure that the copy destination Reader/Writer is operating normally.
Make sure that the copy destination Reader/Writer is normally connected to the
network and that there are no mistakes in the settings.
200B hex
Make sure that the Slave Reader/Writers have started normally before you execute
multi-Reader/Writer functions.
Make sure that the Slave Reader/Writers are normally connected to the network
and that there are no mistakes in the settings.