GET FIRMWARE VERSION

This command reads the firmware version of the Reader/Writer.
 Command Area
Signal/data
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
 Response Area
Signal/data
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RespData/Response Data
Run Mode Program Major
Version
Run Mode Program Minor
Version
Run Mode Program Revision
Safe Mode Program Major
Version
Safe Mode Program Minor
Version
Safe Mode Program Revision
 Execution Example
Reading the Firmware Version When the Run Mode Program Version is Version 1.2.3 and the Safe
Mode Program Version is Version 1.2.2
Command Area
Memory offset
Data name
+2
CmdCode
+4
CmdParam1
+6
CmdParam2
Response Area
Memory offset
Data name
+2
ErrCode
+4
RespInfo1
+6
RespInfo2
+8
RespData[0-1]
+10
RespData[2-3]
+12
RespData[4-5]
+14
RespData[6-7]
+16
RespData[8-9]
+18
RespData[10-11]
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
Data type
Size
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
WORD
2 bytes
Byte +0
Byte +1
2
0
0
1
0
0
0
0
0
0
0
0
Byte +0
Byte +1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Run Mode program version information
0
0
0
2
0
0
0
3
0
0
0
1
0
0
0
2
Safe Mode program version information
0
0
0
2
Host Communications Specifications
Function
2001 hex
0000 hex (Not used.)
0000 hex (Not used.)
Function
Error code
0000 hex (Not used.)
0000 hex (Not used.)
0000 to 0099 hex (BCD)
0000 to 0099 hex (BCD)
0000 to 9999 hex (BCD)
0000 to 0099 hex (BCD)
0000 to 0099 hex (BCD)
0000 to 9999 hex (BCD)
Section 7
RFID System