 System Errors
Error code name
System startup errors
System memory error
Profile error
Hardware faults
IC error
Configuration memory
error
 Device Information
The following table lists the device information that indicates the Reader/Writer in which the error
occurred.
These codes are set in the Response Information 1 field in the response area.
Device information
0000 hex
0100 hex
0200 hex
0300 hex
0400 hex
0500 hex
0600 hex
0700 hex
 Communications Diagnostics Results
The following table lists the communications diagnostic results that are obtained when the Reader/
Writer communicates with an RF Tag.
If communications diagnostics are enabled, these codes are provided to indicate the cause when
diagnostics indicate that communications are unstable.
This information is set in the Response Information 2 field in the response area. When this information
is set, the RF_WAR (communications unstable) signal turns ON.
Communications diagnostics
result
0000 hex
0001 hex
0002 hex
0003 hex
0004 hex
Error code
An error was detected in system memory. A record is stored only in the
F001 hex
system error log.
An error was detected in the profile data. A record is stored only in the
F002 hex
system error log.
F011 hex
An error was detected in an IC in the Reader/Writer.
An error was detected when accessing configuration memory.
F012 hex
An error occurred in the local Reader/Writer.
• An error occurred in the destination Reader/Writer when copying data.
• An error occurred in Slave Reader/Writer No. 1 for multi-Reader/Writer operation.
An error occurred in Slave Reader/Writer No. 2 for multi-Reader/Writer operation.
An error occurred in Slave Reader/Writer No. 3 for multi-Reader/Writer operation.
An error occurred in Slave Reader/Writer No. 4 for multi-Reader/Writer operation.
An error occurred in Slave Reader/Writer No. 5 for multi-Reader/Writer operation.
An error occurred in Slave Reader/Writer No. 6 for multi-Reader/Writer operation.
An error occurred in Slave Reader/Writer No. 7 for multi-Reader/Writer operation.
Normal
Insufficient power to send
Insufficient power to receive
Too much noise
Insufficient signal-to-noise ratio