Set Multi-Reader/Writer Operation - Omron V680S-HMD64-PNT User Manual

Profinet reader/writer
Hide thumbs Also See for V680S-HMD64-PNT:
Table of Contents

Advertisement

Section 7
Host Communications Specifications

SET MULTI-READER/WRITER OPERATION

This command sets multi-Reader/Writer operation.
 Command Area
CmdCode/Command Code
CmdParam1/Command Parameter 1
CmdParam2/Command Parameter 2
CmdData/Command Data
Multi-Reader/Writer Mode
Number of Slave Reader/Writers
IP Address of Slave Reader/
Writer No. 1
IP Address of Slave Reader/
Writer No. 2
IP Address of Slave Reader/
Writer No. 3
IP Address of Slave Reader/
Writer No. 4
IP Address of Slave Reader/
Writer No. 5
IP Address of Slave Reader/
Writer No. 6
IP Address of Slave Reader/
Writer No. 7
 Response Area
ErrCode/Error Code
RespInfo1/Response Information 1
RespInfo2/Response Information 2
RFID System
170
User's Manual
(PROFINET)
Signal/data
Data type
WORD
WORD
WORD
WORD
WORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
DWORD
Signal/data
Data type
WORD
WORD
WORD
Size
2 bytes
1003 hex
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
0000 hex: Disable
2 bytes
0001 hex: Enable Field Extension Mode
0002 hex: Enable High-speed Traveling Mode
Number of Reader/Writers linked with multi-Reader/
Writer operation
2 bytes
0000 to 0007 hex
* Specify 0000 hex if multi-Reader/Writer operation is
disabled.
IP addresses of Slave Reader/Writers
4 bytes
0000 0000 to FFFF FFFF hex
4 bytes
Example: C0A801C8 hex (192.168.1.200)
* Specify 0000 0000 hex if multi-Reader/Writer
operation is disabled or the Slave Reader/Writer is not
4 bytes
used.
4 bytes
4 bytes
4 bytes
4 bytes
Size
2 bytes
Error code
2 bytes
0000 hex (Not used.)
2 bytes
0000 hex (Not used.)
Function
Function