V680S Commands

 Command Codes
The following table lists the command codes that you can specify for execution by the Reader/Writer.
Set these codes in the Command Code field in the command area.
Classification
RF Tag communications
Reader/Writer settings
Reader/Writer information
acquisition
Reader/Writer operation control
 Error Codes
The following tables list the error codes that indicate the response results from the Reader/Writer.
These codes are set in the Error Code field in the response area.
If an error response is returned (i.e., an error code other than 0000 hex), a record is stored in the
command error log in the Reader/Writer. Records are not stored for errors for which responses are not
returned to the host device. Reader/Writer operating errors and system errors are recorded in the
system error log in the Reader/Writer.
 Normal Code
Error code name
Normal end
 Interrupted Processing
Error code name
Communications
canceled
Communications
aborted
Command code
0001 hex
READ ID
0002 hex
READ DATA
0003 hex
WRITE DATA
0004 hex
LOCK
0005 hex
DATA FILL
0006 hex
RF TAG OVERWRITE COUNT CONTROL
0007 hex
RESTORE DATA
0008 hex
COPY DATA
INITIALIZE
1000 hex
SET RF TAG COMMUNICATIONS
1001 hex
GET RF TAG COMMUNICATIONS SETTINGS
1002 hex
1003 hex
SET MULTI-READER/WRITER OPERATION
1004 hex
GET MULTI-READER/WRITER SETTINGS
2000 hex
GET MODEL INFORMATION
2001 hex
GET FIRMWARE VERSION
2002 hex
GET OPERATING TIME
2003 hex
MEASURE NOISE
2004 hex
GET COMMAND ERROR LOG
2005 hex
GET RESTORE INFORMATION
2006 hex
GET MULTI-READER/WRITER STATUS
3000 hex
RESET
Error code
0000 hex
Processing ended normally.
Error code
Processing was canceled when an OFF EXE signal was received before an RF Tag
0001 hex
was detected. (The contents of the RF Tag was not changed, even for a WRITE
DATA command.)
Processing was canceled when an OFF EXE signal was received during
0002 hex
communications with an RF Tag. (For a WRITE DATA command, the contents of
the RF Tag may have been changed.)
Host Communications Specifications
Command name
Description
Description
Section 7
Reference
p.158
p.159
p.160
p.161
p.162
p.163
p.164
p.165
p.167
p.168
p.169
p.170
p.172
p.174
p.175
p.176
p.177
p.178
p.180
p.182
p.183
RFID System
155
User's Manual
(PROFINET)

Advertisement

Table of Contents
loading

This manual is also suitable for:

V680 seriesV680s-hmd63-pntV680s seriesV680s-hmd66-pnt

Table of Contents